Login Get Registered Catalog Browser Contact Us
Electrical Cable, Data Cable, and Specialty Cables

About Nexans

Products and Solutions

Customer Service

Work at Nexans

News and Press

Go

NTSCGECWOEUS 3.6/6 kV red

Send link to this page print Your Nexans contact on this page
NTSCGECWOEUS 3.6/6 kV red 6 kV trailing cable with control cores and concentric monitoring conductor
Standards
National  DIN VDE 0250 part 813; DIN VDE 0250 part 813
Description

Application

For underground mines as well as in tunnels, if monitoring of outer damages is required. The robust construction allows the cable to be used on mobile quipment, on energy lines, as well as for occasional reeling (see also DIN VDE 0298 part 3)

Construction

  • Phase cores: copper conductor, tinned, finely stranded - insulation of dielectrical and thermal high quality, ozone resistant ethylene-propylene rubber (EPR), compound type 3GI3 - individually concentric protection conductor of tinned copper wires applied over insulation
  • Control core: copper conductor, tinned, finely stranded - insulation of dielectrical and thermal high quality, ozone resistant ethylene-propylene rubber (EPR), compound type 3GI3 - 3 control cores laid up with short pitch diameter as a triple
  • 3 phase cores laid-up with 3 control cores in the interstices
  • Inner sheath filling in the interstices - compound type GM1b - concentric monitoring conductor of special steel/copper strands applied on top of an overlapped special conductive tape - outer sheath of chlorinated rubber-like polychloroprene (CR), oil resistant, tear and abrasion resistant, flame retardant, compound type 5GM5

Core colours

  • Phase cores: natural shade
  • Control cores: black, blue, brown

Current carrying capacities acc. to DIN VDE 0118 and 0298 part 4


 TOP
Characteristics
Construction characteristics
Conductor material Tinned copper  
Conductor flexibility Stranded  
Concentric conductor Special steel / copper strands  
Insulation EPR  
Inner sheath Synthetic rubber  
Outer sheath Chloroprene rubber  
Sheath colour Red  
Dimensional characteristics
Number of control cores 9.0  
Cross-section of the control cores 1.5mm²  
Electrical characteristics
Rated Voltage Uo/U (Um) 3.6/6 kV  
maximum pick voltage 0. .. 10.kV  
Usage characteristics
Oil resistance Yes  
Flame retardant Yes  
Max. conductor temperature in service 90°C  
Limit surface temperature fixed installed -40 .. 80°C  
Limit surface temperature, flexible application -25 .. 80°C  
Bending factor when installed 4(xD)  
Dynamic bending factor 7.5(xD)  

 TOP
Conductor cross-section  mm²
Apply
Reset
Results   6/6
Select all Items Part Number Description Conductor cross-section (mm²)
NTSCGECWOEUS 3x16 + 3x16 / 3E + 3x(3x1,5 St) + UEL 16
NTSCGECWOEUS 3x25 + 3x16 / 3E + 3x(3x1,5 St) + UEL 25
NTSCGECWOEUS 3x35 + 3x16 / 3E + 3x(3x1,5 St) + UEL 35
NTSCGECWOEUS 3x50 + 3x25 / 3E + 3x(3x1,5 St) + UEL 50
NTSCGECWOEUS 3x70 + 3x35 / 3E + 3x(3x1,5 St) + UEL 70
NTSCGECWOEUS 3x95 + 3x50 / 3E + 3x(3x1,5 St) + UEL 95
Add to favorites

 TOP
Selling delivery information

Special designs

For example with additional steel wire braid and second outer sheath or cables to international specification, also with deviating monitoring systems

Cable fittings

Cables can be supplied with compatible sealing ends, if required (test certificate incl.)

Further details upon request


Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map