LANmark-350 Patch
Description
Berk-Tek’s LANmark-350 Premium Category 5e UTP cables are designed to meet the most advanced UTP horizontal cable applications.Tested up to 350 MHz, the guaranteed performance of this cable far exceeds the ANSI/TIA/EIA-568-C.2 and ISO/IEC 11801 horizontal cable requirements for PS-NEXT, attenuation, structural return loss, attenuation-to-crosstalk ratio (ACR) and impedance, making it ideal for high-end transmission links supporting today's networking protocols.
Description
Standards
International : ISO/IEC 11801National : ANSI/TIA-568-C.2; UL 444
Description
Construction
Stranded tinned copper wire insulated with polyethylene. Two insulated conductors twisted together to form a pair and four such pairs cabled to form the basic unit jacketed with flame-retardant PVC.
Standards
- North American: ANSI/TIA/EIA-568-C.2, UL 444 and C22.2 No.214-02
- International: ISO/IEC 11801-2nd Edition Category 5, EU Directive 2002/95/EC (RoHS)
Flame Rating
- Patch - UL 1685, CM, IEC 332-1
- UL Listed
Features
- Small, round design
- ETL verified to TIA/EIA-568-C.2 and ISO/IEC 11801
Benefits
- Reliably supports 100BASE-TX Ethernet
- Reduced installation costs and maintenance
- Characterized to 450 MHz, 350 MHz greater than standard
- Lower bit error rates, increases network efficiency and uptime
Characteristics
| Construction characteristics | |
|---|---|
| Type of cable | UTP |
| Dimensional characteristics | |
| Length per reel | 1000.0ft |
| Number of pairs | 4 |
| Usage characteristics | |
| Field of application | Indoor |
| Category | Cat. 5e |
| Fire safety | CM |
| Specific characteristics | |
| See all products | |
| |
Products and services
Docs and info
Technical Data - Physical
|
Technical Data - Physical |
|
Color Code |
||||
|
|
Pair-1 |
White/Blue |
Blue |
|||
|
Conductor |
24 AWG Stranded TC |
Pair-2 |
White/Orange |
Orange |
||
|
Conductor diameter–in. (mm) |
0.024 |
(0.61) |
Pair-3 |
White/Green |
Green |
|
|
Insulated Conductor Diameter- in. (mm) |
0.04 |
(1.02) |
Pair-4 |
White/Brown |
Brown |
|
|
Cable diameter–in. (mm) |
0.215 |
(5.5) |
|
|||
|
Nominal cable weight–lb./kft. (kg/km) |
23 |
(34.5) |
Temperature Rating |
|||
|
Max. installation tension–lb. (N) |
25 |
(110) |
Installation |
0°C to +50°C |
||
|
Min. bend radius–in. (mm) |
1 |
(25.4) |
Operation |
-20°C to +75°C |
||
Technical Data - Parametric Measurements
|
Mutual Capacitance |
5.6 nF/100 m nom. |
|
DC resistance |
9.09 Ohms/100 m max. |
|
Skew |
45 ns/100 m max. |
|
Pair to ground Unbalance |
330 pF/100 m max. |
|
Velocity of Propagation |
70% nom. |
|
Input Impedance |
100 ± 13% 0.772-100 MHz 100 ± [13+15log (F/100)] 100-350 MHz |
|
DC Resistance Unbalance of a Pair |
5% max. |
Technical Data - Electrical
|
FREQ |
SRL |
RL |
IL |
PS-NEXT |
NEXT |
ACR |
PS-ACR |
ELFEXT |
PS-ELFEXT |
|
min. |
min. |
max. |
min. |
min. |
min. |
min. |
min. |
min. |
|
|
1 |
25.5 |
20.0 |
2.4 |
68.3 |
70.3 |
67.9 |
65.9 |
66.8 |
63.8 |
|
4 |
25.5 |
23.3 |
4.8 |
59.3 |
61.3 |
56.5 |
54.5 |
54.7 |
41.7 |
|
10 |
25.5 |
25.5 |
7.7 |
53.3 |
55.3 |
47.7 |
45.7 |
46.8 |
43.8 |
|
20 |
25.5 |
25.0 |
11.0 |
48.8 |
50.8 |
39.8 |
37.8 |
40.7 |
37.7 |
|
31.25 |
24.4 |
24.4 |
13.9 |
45.9 |
47.9 |
34 |
32.0 |
36.9 |
33.9 |
|
62.5 |
22.7 |
22.7 |
20.2 |
41.4 |
43.4 |
23.2 |
21.2 |
30.8 |
27.8 |
|
100 |
21.5 |
21.1 |
26.1 |
38.3 |
40.3 |
14.2 |
12.2 |
26.8 |
23.8 |
|
200 |
19.8 |
19.8 |
38.5 |
33.8 |
35.8 |
— |
— |
20.7 |
17.7 |
|
300 |
18.8 |
18.8 |
48.6 |
31.2 |
33.2 |
— |
— |
17.2 |
15.8 |
|
350 |
18.4 |
18.4 |
53.3 |
30.2 |
32.2 |
— |
— |
15.9 |
12.9 |
|
400 |
18.1 |
18.1 |
57.6 |
29.3 |
31.3 |
— |
— |
14.7 |
11.7 |
|
450 |
17.8 |
17.8 |
61.8 |
28.5 |
30.5 |
— |
— |
13.7 |
10.7 |
-
Supported Category 5e Applications
STANDARD APPLICATION SPEED IEEE 802.3 1000BASE-T 1 Gb/s ATM 155Mb/s 155 Mb/s IEEE 802.3 100BASE-TX 100 Mb/s CDDI 100 Mb/s IEEE 802.3 10BASE-T 10 Mb/s