About Nexans
Products and Solutions
Customer Service
Work at Nexans
News and Press
Construction
24 AWG bare copper wire insulated with polyethylene. Two insulated conductors twisted together to form a pair and four such pairs cabled to form the basic unit which is injected with a water resistant flooding compound and jacketed with UV resistant polyethylene.
Standards
Applications
Berk-Tek's Hyper Plus 5e OSP UTP cable is intended for high speed data applications including:
Features
Benefits
Technical Data - Physical
Color Code
Pair-1
White
Blue
Conductor
24 AWG BC
Pair-2
Orange
Conductor diameter–in. (mm)
0.02
(0.51)
Pair-3
Green
Insulated Conductor Diameter- in. (mm)
0.038
(0.96)
Pair-4
Brown
Cable diameter–in. (mm)
0.207
(5.3)
Nominal cable weight–lb./kft. (kg/km)
20
(30)
Temperature Rating
Max. installation tension–lb. (N)
25
(110)
Installation
0°C to +50°C
Min. bend radius–in. (mm)
1
(25.4)
Operation
-20°C to +60°C
Mutual Capacitance
5.6 nF/100 m max.
DC resistance
9.38 Ohms/100 m max.
Skew
25 ns/100 m max.
Pair to ground Unbalance
330 pF/100 m max.
Velocity of Propagation
72% nom.
Input Impedance
100 ± 15% 1-100 MHz
DC Resistance Unbalance:
5% max.
FREQMHz
SRL(dB)
RL(dB)
IL(dB/100m)
PS-NEXT (dB)
NEXT(dB)
ACR(dB/100m)
PS-ACR(dB/100m)
ELFEXT(dB)
PS-ELFEXT(dB)
min.
max.
25.0
20.0
2.0
62.3
66.3
64.3
60.3
63.8
60.8
4
23.0
4.1
53.3
57.3
53.2
49.2
51.8
48.8
10
6.5
47.3
51.3
44.8
40.8
43.8
16
8.2
44.2
48.3
40.1
36
39.7
36.7
9.3
42.8
46.8
37.5
33.5
37.8
34.8
31.25
23.6
11.7
39.9
43.9
32.2
28.2
33.9
30.9
62.5
21.5
17.0
35.4
39.4
22.4
18.4
27.9
24.9
100
20.1
22.0
32.3
36.3
14.3
10.3
23.8
20.8