Send link to this page print Your Nexans contact on this page
Aluminum Interlock Armored Power and Control Cable UL Type MC, 600 V, 90°C rated - LEAD FREE - Multiple conductors, with ground wire, aluminum interlocked armor, PVC jacket.
Description

FIREX MC cables are rugged armored cables suitable for installation in a wide range of commercial and industrial applications where excellent mechanical and physical properties are required.

 


Applications

FIREX MC is suitable and allowed by the NEC for use in the following applications:

  • for power, lighting and control circuits and as a branch circuits and power feeders in industrial, commercial, institutional and residential installations up to 600 V.
  • fished or embedded in plaster and concrete.
  • direct buried or used as an aerial cable when fixed to a messenger support cable.
  • used in concealed or exposed applications.
  • installed in cable trays and other raceways.
  • in Class I and II, Division 2 as well Class III, Division 1 and 2 hazardous locations.
  • under raised floors of information technology rooms.
  • where exposed to harsh chemicals and vapors

 


Identification of Conductors

Power and control:
sizes #14 AWG to #10 AWG: Method #1-E2 per ICEA S-73-532
sizes #8 AWG to 500 kcmil: Method #4 per ICEA S-73-532

 


Bending Radius

Fixed position: 7 x cable overall diameter
During pulling: 12 x cable overall diameter

 


Specifications

  • Meets UL 44, XHHW-2 600V conductors
  • Meets UL 1569 requirements for Type MC, Metal Clad cables
  • Designated Type MC per NEC Article 330

 


Product features

  • Cables are UL listed as Type MC, 600 V
  • UL listed insulated conductors
  • Cables pass UL 1685 and IEEE 383 vertical tray fire tests at 70,000 BTU/hr, ICEA T-29-520 fire test at 210,000 BTU/hr, IEEE 1202 and CSA FT4
  • Cables exhibit a -25°C cold bend rating with suitable precautions
  • Temperature rating of 90°C dry and wet
  • 130°C emergency rating and 250°C short circuit rating
  • Excellent mechanical and physical properties
  • Sunlight and oil resistant jacket
  • LEAD FREE
  • Suitable for direct burial and use in cable tray and embedment in concrete
  • Can be installed in hazardous locations designated Class I or Class II Division  2,  NEC Articles 501.10(B), 502.10(B) and Class III Division 1 and 2, NEC Article 503.10 (A) and (B)

 


 TOP
Characteristics
Electrical characteristics
Operating voltage 600V  

 TOP
FIREX® MC 4 Conductor

Part 
Number

Cond.
Size

Insulation 
Thickness

Ground
Wire Size

Nominal Diameter
over Armor

Jacket 
Thickness

Nominal Diameter
over Jacket

Approximate Net
Cable Weight

Ampacity

AWG/kcmil

mils

mm

AWG

inches

mm

mils

mm

inches

mm

lb/kft

kg/km

amps (1)

660702

8(7w)

45

1.14

10(7w)

0.783

19.89

50

1.27

0.889

22.58

462

688

55

660703

6(7w)

45

1.14

8(7w)

0.879

22.33

50

1.27

0.985

25.01

637

947

75

651216

4(7w)

45

1.14

8(7w)

1.005

25.53

50

1.27

1.113

28.27

893

1329

95

649293

2(7w)

45

1.14

6(7w)

1.148

29.17

50

1.27

1.256

31.90

1298

1932

130

662360

1(19w)

55

1.40

6(7w)

1.260

32.00

50

1.27

1.368

34.74

1547

2302

150

660704

1/0(19w)

55

1.40

6(7w)

1.379

35.02

50

1.27

1.487

37.77

1901

2829

170

645481

2/0(19w)

55

1.40

6(7w)

1.483

37.67

50

1.27

1.591

40.42

2293

3412

195

662125

3/0(19w)

55

1.40

4(7w)

1.586

40.29

60

1.52

1.714

43.53

2825

4204

225

649301

4/0(19w)

55

1.40

4(7w)

1.720

43.68

60

1.52

1.847

46.92

3474

5170

260

660407

250(37w)

65

1.65

4(7w)

2.042

51.86

60

1.52

2.171

55.15

4073

6062

290

660673

350(37w)

65

1.65

3(7w)

2.293

58.23

75

1.92

2.454

62.33

5817

8657

350

640508

500(37w)

65

1.65

2(7w)

2.603

66.12

75

1.92

2.765

70.22

7890

11742

430

(1) Ampacities are in accordance with Table 310.16 of the NEC for conductors in raceway or direct buried at 30°C ambient temperature and 90°C
conductor temperature, where the 4th conductor is the neutral of a balanced 3 phase system. If the 4th conductor is to be used as a current
carrying conductor, then a derating factor of 80% is to be applied to the ampacity of all 4 conductors, as per Article 310.15(B)(2)(a) of the NEC.
For correction factors for different ambient temperatures and ampacities at different conductor temperatures, see Table 310.16 of the NEC.


 TOP
Selling delivery information

Options

The following constructions can be provided on special orders:

  • Aluminum conductors
  • Steel interlock armor
  • Extra ground wires
  • Special color or number coding
  • Specially colored jackets
  • Other constructions and combinations (some manufacturing restrictions apply)

 