Speed, simplicity and performance. You find them all in the OCA of the OneReach System. Power and data transmission are supported within a single jacket through the use of Berk-Tek CL3R-OF rated composite copper/fiber cable. These cables combine 12 AWG or 18 AWG stranded conductors with either tight-buffered or loose tube optical fiber cable designs to support 1- or 4-port remote devices.
Building upon the strength of the innovative cable design, assemblies are built to the specific length requirements of each project, and arrive on-site with pre-tested optical fiber connectors and an M8 connector for power on the remote device end, ready to install. The local end of the assembly attaches effortlessly to the local media module or power injector chassis with standard LC connectors and easy to use screw terminals.
Rapid and reliable installation is the norm with OneReach, which lets you take PoE to new distances. The stranded conductors provide enough power to support PoE to distances well beyond the 100 meters supported through traditional twisted pair cabling.
Benefits
Number of Conductors
Conductor Gauge Size
Cable Type
Fiber Type
# of Fibers
Cable Part Number
Application
Supported Distanceto RPP: PoE
ft.
m
2
18, 18
Tight buffer
OM1
BHCR02CAA04NFNM8NPxxx
1-port assembly
1000
305
12, 12
BHCR02CDD04NFNM8NPxxx
3850
1175
3
18, 18, 18
Dry loose tube
8
BACR08CAAA77NNM8NPxxx
4-port assembly
250
75
12, 12, 18
BACR08CADD77NNM8NPxxx
960
290
Dry loose tube, Interlock Armored
BACRK08CAAA77NNM8NPxxx
BACRK08CADD77NNM8NPxxx
IMPORTANT NOTICE: This product specification is provided for informational purposes only in order to illustrate typical product constructions, applications and/or methods of installation. Because conditions of actual installation and use are unique and will vary, Berk-Tek makes no representation or warranty as to the reliability, accuracy or completeness of this data, even if Berk-Tek is aware of the product's intended use or purpose. Furthermore, this data does not constitute, nor should it be regarded or relied upon, as professional engineering advice. Installation of cable should only be done by qualified personnel and in conformance with all safety, electrical and other applicable codes, standards, rules or regulations. Appropriate and correct product selection, installation and use, and compliance with all such codes, standards, rules and regulations, is a customer/end-user responsibility. Product specifications, standards, programs or services are subject to improvement or changes without notice. Berk-Tek accepts no liability for typographical errors, technical inaccuracies, omissions or misuse of the information contained herein. Changes will be periodically made to address any such issues.