Login Get Registered Catalog Browser Contact Us
Electrical Cable, Data Cable, and Specialty Cables

About Nexans

Products and Solutions

Customer Service

Work at Nexans

News and Press

Go

ENERGEX® THHN/THWN-2/MTW

Send link to this page print Your Nexans contact on this page
PVC/Nylon Cable, Copper Conductors, 600 Volts, 90°C dry rated - LEAD FREE
Standards
National  UL 1063; UL 83
Description

Application

Nexans ENERGEX® THHN/THWN-2/MTW* is a general purpose wiring product for use in power, lighting and control circuits.  It can be used in conduit, ducts and trays for service feeders and branch circuits in industrial and commercial installations.  When used in accordance with the 2008 or 2011 NEC, THHN/THWN-2 is suitable for use in wet and dry locations, at conductor temperatures not exceeding 90ºC or for use in oil or coolants at conductor temperatures not exceeding 75ºC.  THHN/THWN-2 is gasoline and oil resistant II.  When used as Machine Tool Wire (MTW) it is rated at 90ºC in dry locations and 60ºC in wet locations or when exposed to oil or coolants.

Nexans THHN/THWN-2/MTW wire is LEAD FREE and RoHS compliant. 

Construction

Conductor
Solid bare, annealed copper per ASTM B3.
Stranded bare annealed copper per ASTM B3 and ASTM B8.  14, 12, 10 and 8 AWG and ASTM B8 for sizes 6 AWG and larger.

Insulation:
Color coded polyvinyl chloride (PVC), heat, moisture and flame retardant compound per UL 83 and UL 1063.

Covering:
A tough abrasion resistant polyamide (Nylon) covering.

Specifications

  • Nexans ENERGEX ® THHN/THWN-2 or MTW meets or exceeds all applicable ASTM specifications
  • UL 83: Thermoplastic-Insulated Wires and Cables
  • UL 1063: Machine-Tool Wires and Cables (stranded cables only)
  • NEMA WC70 / ICEA S-95-658: Power Cables Rated 2000V or Less for the Distribution of Electrical Energy
  • NEMA WC70/ICEA S-95-658
  • Federal Specification A-A-59544 and requirements of the NEC
  • CSA C22.2 No. 75: Thermoplastic Insulated Wires and Cables
  • 14 AWG through 750 kcmil are rated VW-1. 
  • Sizes 1/0 and larger are listed for CT use
  • Black sizes 1/0 AWG and larger are sunlight resistant
  • Voltage rating - 600 volts.

Surface Print Legend (example)

NEXANS-C 500 kcmil (253mm2) TYPE MTW OR THHN OR THWN-2 GRII SR FOR CT USE VW-1 600V (UL) LEAD FREE (MFG. DATE)

 

 



Related documents
  ENERGEX® THHN/THWN-2/MTW Copper Part No.  (69.5kb)



 TOP
Characteristics
Construction characteristics
Insulating material PVC  
Conductor material Copper  
Lead free Yes  
Electrical characteristics
Maximum operating voltage 600V  
Usage characteristics
RoHS conform Yes  
Maximum operating temperature 90°C  

 TOP
ENERGEX® THHN/THWN-2/MTW Copper

Conductor
Size
AWG/kcmil

PVC Insulation
Thickness

Nylon
Thickness

Nominal Diameter

Approximate Net
Cable Weight

Ampacity

Amps

mils

mm

mils

mm

inches

mm

lbs/kft

kg/km

60ºC

75ºC

90ºC

14 (1)

15

0.38

4

0.10

0.11

2.80

15

22.3

15

15

15

12 (1)

15

0.38

4

0.10

0.12

3.10

23

34.2

20

20

20

10 (1)

20

0.51

4

0.10

0.15

3.80

37

53.6

30

30

30

14 (19)

15

0.38

4

0.10

0.11

2.80

16

23.8

15

15

15

12 (19)

15

0.38

4

0.10

0.13

3.80

24

35.7

20

20

20

10 (19)

20

0.51

4

0.10

0.17

4.30

39

58.0

30

30

30

8 (19)

30

0.76

5

0.13

0.22

5.60

63

93.7

40

50

55

6 (19)

30

0.76

5

0.13

0.26

6.60

98

145

55

65

75

4 (19)

40

1.01

6

0.15

0.33

8.40

157

234

70

85

95

3 (19)

40

1.01

6

0.15

0.36

9.10

193

287

85

100

110

2 (19)

40

1.01

6

0.15

0.39

9.90

240

357

95

115

130

1 (19)

50

1.27

7

0.18

0.43

10.9

300

446

110

130

150

1/0 (19)

50

1.27

7

0.18

0.47

12.0

376

560

125

150

170

2/0 (19)

50

1.27

7

0.18

0.52

13.2

467

695

145

175

195

3/0 (19)

50

1.27

7

0.18

0.57

14.5

581

864

165

200

225

4/0 (19)

50

1.27

7

0.18

0.64

16.0

724

1077

195

230

260

250 (37)

60

1.52

8

0.20

0.69

17.4

855

1272

215

255

290

300 (37)

60

1.52

8

0.20

0.76

19.3

1022

1521

240

285

320

350 (37)

60

1.52

8

0.20

0.79

20.1

1191

1772

260

310

350

400 (37)

60

1.52

8

0.20

0.85

21.6

1345

2001

280

335

380

500 (37)

60

1.52

8

0.20

0.94

23.9

1668

2482

320

380

430

600 (61)

70

1.78

9

0.23

1.10

27.9

1994

2967

355

420

475

750 (61)

70

1.78

9

0.23

1.16

29.5

2465

3668

400

475

535

60ºC - When terminated to equipment for circuits rated 100 amperes or less or marked for conductor 
sizes 14 through 1 AWG.  For MTW in wet locations or when exposed to oil or coolant.
75°C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors 
larger than size 1 AWG. THWN-2 when exposed to oil or coolant.
90°C - THHN dry locations.  THWN-2 wet or dry locations.  For ampacity derating purposes.
Available colors:  Black, White, Red, Blue, Green, Yellow, Brown, Orange, Purple, Gray, Pink.

Notes:
• Where stated, “nominal” and “approximate” values are provided for information purposes only and 
are subject to standard manufacturing tolerances.
• Ampacities are in accordance with NEC 2008 and NEC 2011 Article 310.15, which are based on 
NEC 2008 Table 310.16 or NEC 2011 Table 310.15(B)(16) for conductors in a raceway or direct 
buried at 30°C ambient temperature.
• For correction factors for different ambient temperatures and ampacities at different conductor 
temperature ratings see NEC 2008 Table 310.16 or NEC 2011 Table 310.15(B)(16).
• NEC 2008 and NEC 2011 Article 240.4(D) requires that overcurrent protection not exceed 
15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper 
conductors after any correction factors for ambient temperature and number of conductors 
have been applied. Exceptions to this may be covered in NEC 2008 and NEC 2011 
Article 240.4(E) through (G).


 TOP
Selling delivery information

Product Features

  • Sizes 8 AWG - to 600 kcmil available in various colors from stock
  • Cables are UL listed as Type THHN/THWN-2/MTW*
  • Meets UL VW-1 flame test requirements
  • CT rated for sizes 1/0 AWG and larger
  • Black 1/0 AWG and larger is sunlight resistant
  • High heat and moisture resistant
  • THWN-2 90ºC rated for dry and wet locations
  • Gasoline and Oil Resistant II
  • Small diameter for improved conduit fill
  • LEAD FREE and RoHS compliant

 

Packaging

  • 14 & 12 AWG: 4 x 500' spools (2000' per carton) or 2500' reel
  • 10 AWG: 2 x 500' spools (1000' per carton) or 2500' reel
  • 8 AWG - 350 kcmil: 500', 1000', 2500' or 5000' reel
  • 400 kcmil - 500 kcmil: 500', 1000', or 2500' reel
  • 600 kcmil - 750 kcmil: 500' reel


* Only stranded cables are MTW listed per UL 1063.


ENERGEX® THHN/THWN-2/MTW    ENERGEX® THHN/THWN-2/MTW Copper Part No. (69 kB)