CORFLEX® VFD Armored Variable Frequency Drive Cable UL Type MC HL, 600V, 90°C rated - LEAD FREE
Standards
National  ICEA S-73-532; UL 1569; UL 2225; UL 44
Description

3 conductor with 3 ground wires, continuous corrugated and welded, impervious aluminum sheath, PVC jacket

CORFLEX® VFD cables are designed to improve the operating performance of variable frequency drive systems. The 600 volt CORFLEX® VFD cables provide excellent shielding from high frequency noise that can interfere with data and control signals. Nexans CORFLEX® sheath provides a long term low resistance path to ground to protect the drive system. Cable grounds provide the best cancellation and lowest net injected ground current into the drive system protecting against common mode currents which impair the drive unit electronic performance and shorten the drive life span. Cable grounds also ensure a balanced, low resistance path to ground to reduce the chance of motor failure due to bearing currents. The CORFLEX® VFD cable design has been shown to be the best of eight cable constructions studied for use between a VFD and the motor. This information can be found in an IEEE paper called "Evaluation of Motor Power Cables for PWM AC Drives" published in 1996.

Construction

Conductor:
Bare, annealed copper conforming to ASTM B3 and Class B stranded in accordance with ASTM B8.

Insulation:
Crosslinked polyethylene type XHHW-2 per UL 44.

Assembly:
Conductors are cabled in concentric layers with three grounding wires, interstices are filled with suitable non-hygroscopic fillers, as required. A binder tape of synthetic material assembles the core in an essentially round configuration.

Armor:
Continuous corrugated and welded, impervious aluminum sheath with no more than 0.2% trace copper providing complete protection against liquid and gas ingress. It also provides excellent mechanical protection, additional electrostatic shielding, and serves as an easy means of grounding equipment.

Jacket:
Overall black polyvinyl chloride jacket per UL 1569, 90°C temperature rating; low gas emission; limited flame spread and excellent corrosion resistance.

Conductor Identification:
Sizes 14 AWG to 2 AWG: Method #1-E2 per ICEA S-73-532
Sizes 1 AWG to 500 kcmil: Method #4 per ICEA S-73-532

Bending Radius:
Fixed position: 7 x cable overall diameter
During pulling: 12 x cable overall diameter

Specifications

  • Meets UL 44, XHHW-2 600V conductors
  • Meets UL 1569 requirements for Type MC, Metal Clad cables
  • Meets UL 2225 for Hazardous Locations
  • Designated Type MC as per NEC 2008 and NEC 2011 Article 330
  • Meets CSA C22.2 No. 123-08 for Aluminum Sheathed Cables
  • Meets CSA C22.2 No. 174-M1984 for Hazardous Locations


Related documents
  Corflex Part Numbers  (12.1kb)



 TOP
Characteristics
Construction characteristics
Conductor material Copper  
Lead free Yes  
Electrical characteristics
Maximum operating voltage 600V  
Usage characteristics
Maximum operating temperature 90°C  

 TOP
Corflex VFD - 3 Conductors with 3 Bare Grounds

Cond.
Size

Insulation 
Thickness

Ground
Wire Size

Nominal 
Diameter
over Core (D1)

Nominal 
Diameter
over Sheath (D2)

Jacket 
Thickness
(T1)

Nominal 
Diameter
over Jacket (D3)

Approximate
Net
Cable Weight

Ampacity

AWG/kcmil

mils

mm

AWG

inches

mm

inches

mm

mils

mm

inches

mm

lb/kft

kg/km

amps (1)

14(7w)

30

0.76

3x18(7w)

0.390

9.91

0.555

14.10

50

1.27

0.660

16.80

200

298

20

12(7w)

30

0.76

3x16(7w)

0.340

8.64

0.555

14.10

50

1.27

0.660

16.80

226

336

30

10(7w)

30

0.76

3x14(7w)

0.450

11.43

0.620

15.75

50

1.27

0.725

18.40

312

464

40

8(7w)

45

1.14

3x14(7w)

0.520

13.21

0.750

19.05

50

1.27

0.838

21.29

413

615

55

6(7w)

45

1.14

3x12(7w)

0.600

15.24

0.802

20.37

50

1.27

0.905

22.99

542

807

75

4(7w)

45

1.14

3x12(7w)

0.700

17.78

0.937

23.80

50

1.27

1.039

26.39

735

1094

95

2(7w)

45

1.14

3x10(7w)

0.830

21.08

1.127

28.63

50

1.27

1.232

31.29

1097

1633

130

1(19w)

55

1.40

3x10(7w)

0.950

24.13

1.230

31.24

50

1.27

1.320

33.53

1330

1979

150

1/0(19w)

55

1.40

3x10(7w)

1.040

26.42

1.350

34.29

50

1.27

1.473

37.41

1592

2369

170

2/0(19w)

55

1.40

3x10(7w)

1.126

28.61

1.422

36.12

60

1.52

1.526

38.77

1882

2801

195

3/0(19w)

55

1.40

3x8(7w)

1.250

31.75

1.606

40.79

60

1.52

1.739

44.18

2400

3570

225

4/0(19w)

55

1.40

3x8(7w)

1.360

34.55

1.734

44.04

60

1.52

1.867

47.43

2910

4330

260

250(37w)

65

1.65

3x8(7w)

1.477

37.52

1.925

48.89

60

1.52

2.058

52.27

3316

4934

290

350(37w)

65

1.65

3x6(7w)

1.730

43.94

2.220

56.39

60

1.52

2.350

59.69

4560

6786

350

500(37w)

65

1.65

3x6(7w)

1.996

50.70

2.370

60.20

60

1.52

2.504

63.61

5988

8910

430

 (1)   Ampacities are in accordance with NEC 2008 Table 310.16 or NEC 2011 Table 310.15(B)(16) for conductors in raceway or direct buried 
at 30°C ambient temperature and 90°C conductor temperature.
The overcurrent protection shall not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG and 30 amperes for 10 AWG copper conductors after 
any correction factors for ambient temperature and number of conductors have been applied (NEC 2008 and NEC 2011 Article 240.4(D)).
For correction factors for different ambient temperatures and ampacities at different conductor temperatures see NEC 2008 Table 310.16 or 
NEC 2011 Table 310.15(B)(16).


 TOP
Selling delivery information

Product Features

 

* UL approved cables Type MC, 600V; File No. E47409
* UL approved insulated conductors
* Cables pass UL 1685 and IEEE 383 vertical tray fire tests at 70,000 BTU/hr, ICEA T-29-520 fire test at 210,000 BTU/hr, IEC 332-3 category A fire test, IEEE 1202 and CSA FT4
Cables are American Bureau of Shipping (ABS) listed as CWC MC Type MC
* Cables exhibit a low temperature rating of -25°C impact and –40°C bend with suitable precautions
* Temperature rating of 90°C dry and wet
* 130°C emergency rating & 250°C short circuit rating
* Continuous, impervious aluminum sheath corrugated for flexibility, prevents ingress of moisture, gases and liquids
* Aluminum sheath cross-section exceeds requirements of the NEC Section 250.122 for grounding conductor
* Sheath provides good electronic shielding so that CORFLEX® can be used in certain instrumentation applications when adequately grounded
* Excellent mechanical and physical properties
* Sunlight resistant jacket
* Suitable for direct burial and use in cable tray and embedment in concrete

* LEAD FREE

Options

The following constructions can be provided on special orders:

* Special color or number coding
* Specially colored jackets
* UL 1309 listing and marking


CORFLEX® VFD   Corflex Part Numbers (12 kB)