ULTREX® VN Unshielded Tray Cable - Composite

Send link to this page print Your Nexans contact on this page
Type THHN/THWN-2: UL Type TC / TC-ER, 600 V, 90°C dry / wet rated – LEAD FREE - Composite: 4 Control Conductors wtih 3 Power Conductors and 1 Ground Wire
Standards
National  ICEA S-73-532; ICEA S-95-658; UL 1277; UL 83
Description

Applications

Nexans 600 V Ultrex VN Tray Cables are listed as type TC / TC-ER under UL 1277 Electrical Power and Control Cables.  These cables may be installed in wet or dry locations; in cable trays, raceways and open air; and are suitable for exposure to weather, direct burial and for Class I, Div. 2 (also Zone 2) and Class II, Div. 2 hazardous locations per NEC 2008 and NEC 2011.  Cables with three or more conductors are UL listed for exposed runs (ER) when installed in accordance with NEC 2008 and NEC 2011 Article 336.10(7).

Construction

Conductor:
Bare, annealed copper conforming to ASTM B3 and Class stranded in accordance to ASTM B8, from 14 AWG to 500 kcmil. Compressed copper for 14 AWG through 500 kcmil.

Insulation:
Flame-retardant PVC/Nylon type THHN/THWN-2 per UL 83 for sizes 14 AWG to 500 kcmil.

Assembly:
Non-shielded:  cables with 3 or more conductors and cabled in concentric layers with interstices filled with suitable fillers, as required.  Two-conductor cables are supplied in a flat/parallel configuration.  Ground wires, are sized as required by UL 1277 (refer to applicable product tables for the standard sizes provided).  Sizes 14 AWG to 6 AWG have an insulated green ground wire.  Size 4 AWG and larger have a bare ground wire.  Where necessary, a binder tape of synthetic material assembles the core in a tight circular configuration. 

Shielded: cabled in concentric layers with interstices filled with suitable fillers as required.  A helically wrapped aluminum tape, with synthetic backing, gives 100% shielding.  A tinned copper drain wire is placed in contact with the aluminum side of the tape, to lower the resistance and to assist in the termination of the shield.


Jacket:

UL listed sunlight and moisture resistant, sequentially marked, black, flame retardant polyvinyl chloride (PVC) material meeting the requirements of UL 1277. A Nylon ripcord is included for ease of jacket removal. Jacket surface is printed with required UL / NEC code information and sequential footage markings.

NEXANS-C ULTREX-VN 600V TC-ER 3/C-12 AWG THHN/THWN-2 SUN RES DIR BUR (UL) ROHS (mm/dd/yyyy)

Conductor Identification:

Composite

Power and Control:  black with number coding per Method 4 of ICEA S-73-532

 

See details in Conductor Identification Charts. 


 TOP
Characteristics
Construction characteristics
Conductor material Copper  
Electrical characteristics
Rated Voltage Uo/U (Um) 600 V  
Usage characteristics
Maximum operating temperature 90°C  

 TOP
ULTREX® VN Unshielded Tray Cable - Composite
UL Type TC / TC-ER, 600 V, 90°C dry / wet rated – LEAD FREE Composite Conductors Type THHN/THWN-2 with Ground Composite - 4 Control Conductors with 3 Power conductors and 1 Ground Wire

Part 
Number

Control 
Size

Insulation
Thickness 
PVC/Nylon

Power
 Size

Insulation 
Thickness 
PVC/Nylon

Ground 
Size

Jacket 
Thickness

Nominal 
Diameter 
over Jacket

Approximate 
Net 
Cable Weight

Control 
Ampacity

Power 
Ampacity

AWG

mils

mm

AWG

mils

mm

AWG

mils

mm

inches

mm

lb/kft

kg/km

amps

amps 

684126

12

15/4

0.38/0.10

10

20/4

0.51/0.10

10

60

1.52

0.585

14.86

320

476

21

28

627042

12

15/4

0.38/0.10

8

30/5

0.76/0.13

8

60

1.52

0.675

17.15

405

603

21

55

627810

12

15/4

0.38/0.10

6

30/5

0.76/0.13

8

60

1.52

0.720

18.29

530

789

21

75

697680

12

15/4

0.38/0.10

4

40/6

1.02/0.15

6

80

2.03

0.890

22.61

760

1131

21

95

682773

12

15/4

0.38/0.10

2

40/6

1.02/0.15

6

80

2.03

1.015

25.78

1061

1579

21

130

Bend Radius:    5 x overall diameter installed 
                        8 x overall diameter during installation pull-in.
Notes:

• Dimensions and weights shown are nominal values, subject to standard industry tolerances.
• Cables are UL listed for exposed runs (ER) when installed in accordance with 
NEC 2008 and NEC 2011 Article 336.10(7).
• Cables with different conductor counts and bare or insulated grounds are also available.
• Ampacities are in accordance with NEC 2008 Table 310.16 or NEC 2011 Table 310.15(B)(16)
for conductors in a raceway or direct buried at 30°C ambient temperature and 90°C rated 
conductors. Ampacities for cables having more than three conductors have been derated 
per NEC 2008 Table 310.15(B)(2)(a) or NEC 2011 Table 310.15(B)(3)(a). 
• For correction factors for different ambient temperatures and ampacities at different 
conductor temperature ratings see NEC 2008 Table 310.16 or NEC 2011 Table 310.15(B)(16).
• NEC 2008 and NEC 2011 Article 240.4(D) requires that overcurrent protection not exceed 
20 amperes for 12 AWG, 30 amperes for 10 AWG copper conductors after any correction 
factors for ambient temperature and number of conductors have been applied.  
Exceptions to this may be covered in NEC 2008 and NEC 2011 
Article 240.4(E) through (G).

Color codes:
• Power and Control conductors are black with number coding per
  Method 4 of ICEA S-73-532.


 TOP
Selling delivery information

Options

The following constructions can be provided on special orders:

* Dow Construction
* DuPont Construction
* Different conductor identification methods

 

* Use in Hazardous locations:
Please note that no investigation of these cables has been performed regarding the transmission of gases or vapors through the core. When these cables are used in hazardous locations they should be sealed properly as required by the NEC.


Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map