Instrumentation TC - 600 V - PVC/Nylon Insulated

Send link to this page print Your Nexans contact on this page
600 V, PVC/Nylon Insulated, 90°C, Unshielded Paris or Triads with Overall Shield, Shielded Pairs or Triads with Overall Shield - LEAD FREE, Type TC - UL 1277 - NEC ART 336
Description

Applications

The 600 V Instrumentation Cables are listed as Type TC per UL 1277. These cables are suitable for installations as outlined in NEC ART 336.

NEXANS Instrumentation Cable is LEAD FREE and RoHS Compliant.

 

Construction

Conductor: bare, annealed copper conforming to ASTM B-3 and Class B stranded in accordance to ASTM B-8.

Insulation: PVC/Nylon Type TFN in accordance with UL 66, flame retardant, 90°C temperature rating.

Insulation Shield (on shielded pair/triad constructions): aluminum foil/polyester shield helically wrapped to provide 100% coverage with a tinned copper drain wire that is two gauge sizes smaller than the circuit conductors.  These shields are electrically isolated from each other.

Assembly: pairs/triads are cabled in concentric layers. In the case of unshielded pairs/triads, they are cabled at staggered lengths to reduce crosstalk.

Overall cable shield: aluminum foil/polyester shield helically wrapped to provide 100% coverage with a tinned copper drain wire that is the same size as the circuit conductors, with the exception of single pair/triad constructions where the drain wire is two gauge sizes smaller than the circuit conductors.

Jacket: UL listed sunlight and moisture resistant, sequentially length marked, black, flame retardant polyvinyl chloride material.  A Nylon ripcord is included for ease of jacket removal.

 

Conductor Identification

Pairs: black/white and number coded
Triads: black/white/red and number coded

 

Bending Radius

Fixed Position: 5 x cable overall diameter
During Installation: 8 x cable overall diameter

 

Specifications

  • Meets UL 66, TFN rated 90°C 600 V conductors
  • Meets UL requirements for Type TC
  • Designated Type TC per NEC ART 336
     


Related documents
  Instrumentation Electrical Properties  (724.5kb)
  Instrumentation Product & Cu Conductor data 600V  (781.0kb)



 TOP
Characteristics
Construction characteristics
Conductor material Bare annealed copper  
Outer sheath Tight buffer  

 TOP
Electrostatic shielding  
Apply
Reset
Results   4/4
Select all Items Part Number Description Electrostatic shielding
Overall Shielded Pairs Instrumentation TC - 600 V - PVC Insulated, PVC Jacketed Overall Shielded
Overall Shielded Triads Instrumentation TC - 600 V - PVC Insulated, PVC Jacketed Overall Shielded
Individual and Overall Shielded Pairs Instrumentation TC - 600 V - PVC Insulated, PVC Jacketed Individual and Overall Shielded
Individual and Overall Shielded Triads Instrumentation TC - 600 V - PVC Insulated, PVC Jacketed Individual and Overall Shielded
Add to favorites

 TOP
Selling delivery information

Options

The following constructions can be provided on special orders:

  • Tinned copper conductors
  • When increased mechanical, chemical, or environmental protection is required, cables can be supplied with a continuously corrugated aluminum and an outer PVC jacket.
  • Interlocked aluminum armor with or without an additional outer PVC jacket
  • Conductors with alternate color / identification codes
  • Alternate jacket colors 

* Use in Hazardous locations:

Please note that no investigation of these cables has been performed regarding the transmission of gases or vapours through the core.  When these cables are used in hazardous locations they should be sealed properly as required by the NEC.


Instrumentation TC - 600 V - PVC/Nylon Insulated   Instrumentation Electrical Properties (724 kB)
Instrumentation TC - 600 V - PVC/Nylon Insulated   Instrumentation Product & Cu Conductor data 600V (781 kB)