216 x OM2 Adventum Plenum with Interlock Armor Berk-Tek’s Adventum Armor-Tek™ products consist of indoor/outdoor rated fiber optic loose tube cables encased with an aluminum or steel spirally wrapped armor in an interlocking configuration. The armored cable is then covered with a plenum rated jacket to prevent snags during installation.
REFERENCES
LTPK12B216ZB3515/55
Standards
Description
Characteristics
Related Information
Standards
International  EN 50173; ISO/IEC 11801
National  ANSI/ICEA S-104-696; ANSI/ICEA S-87-640; ANSI/TIA-568-C.3; Telcordia GR-409
Description

Construction

Loose tube cable constructions (up to 432 optical fibers) with aluminum interlock armor and an overall plenum flame rated jacket.  Steel interlock is also available.

  

Applications

Armor-Tek fiber cables can be used in any of the following installation enviroments:  indoor/outdoor,  in backbones, between closets and in fiber to the desk.  Armor-Tek is a viable and cost effective solution for applications where a pathway is beyond its full ratio, for areas where extra physical security is a concern, in fast track installations, between buildings, direct buried, or in trays. 

Berk-Tek recommends installation procedures per ANSI/TIA-758, Customer-owned Outside Plant Telecommunications Infrastructure Standard.

Berk-Tek's Adventum Loose Tube fiber optic cables (U.S. Patent No. 6,178,278) are suitable for all passive and active optical network designs requiring high speed data applications, including (but not limited to):

 

  • 10BASE-FL
  • 100BASE-SX/100BASE-FX
  • ATM 155/ATM622
  • 1000BASE-SX/1000BASE-LX
  • Fibre Channel 1.062/2.125
  • 10GBASE-SR/SW
  • 10GBASE-LX4
  • 40/100 GbE

 

Features

  • Multimode, Single-mode and GIGAlite™ fibers
  • Available with new bend-optimized single-mode fibers
  • Jacketed armor remains flexible due to the spiral wrap armoring process
  • Easy one-pull installation into any environment
  • Compact outside diameters when compared to plenum innerduct or conduit
  • High tensile strength, crush resistant
  • Available Harsh Environment (HE), cables offer superior resistance to chemicals and fuels.  Suitable for Petro-Chemical, Industrial, and airport installations.

 

Benefits

  • Eliminates the need for conduit or plenum innerduct
  • Significant cost savings in both materials and labor - up to 25%
  • Accommodates last minute relocations or pathway changes
  • Provides a higher concentration of cables in an area than conduit
  • Can be installed in campus environments due to the durability and indoor/outdoor rating of the cable
  • Armor provides crush protection and protection from rodent attacks


Related links
Breakout Kits - Loose Tube   Breakout Kits - Loose Tube



 TOP
Characteristics
Construction characteristics
Fiber optic type OM2 50/125  
Type of cable Loose tube  
Outer sheath Plenum  
Sheath colour Orange  
Armour type Aluminum Interlock  
Dimensional characteristics
Tube diameter 3mm  
Number of optical fibres 216  
Nominal outer diameter 1.004in  
Nominal outer diameter 25.5mm  
Approximate weight 331lb/kft  
Approximate weight 493kg/km  
Transmission characteristics
Optical performance ZB (50/125 FDDI, OM2)  
Attenuation, max. 850 nm (cabled) 3.5dB/km  
Attenuation, max. 1300 nm (cabled) 1.5dB/km  
Mechanical characteristics
Maximum installation tension 1000lb  
Maximum installation tension 4448.0N  
Max. Load. Long Term (lbs) 300.0lb  
Max. Load. Long Term 1335.0N  
Crush resistance per TIA/EIA FOTP-41 440N/cm  
Cable flexibility per TIA/EIA FOTP-104 100 cycles  
Impacts per TIA/EIA FOTP-25 2 at 8.83 N-m  
Usage characteristics
Minimum Bending Radius - Install 15.1in  
Minimum Bend Radius - Install 38.3cm  
Minimum Bending Radius - LongTerm 10in  
Minimum Bending Radius - LongTerm 25.5cm  
RoHS conform Yes  
Operating temperature, range -40 .. 75°C  
Ambient installation temperature, range -20 .. 60°C  
Storage temperature, range -60 .. 85°C  
Field of application Indoor, Outdoor  

 TOP
Sheath Colors

Fiber Type

ISO-TIA
Standard

Effective Modal
BW @ 850 nm

Overfilled Launch
BW @ 850 nm

Attenuation
@ 850 nm

Attenuation
@ 1300 nm

Attenuation
@ 1550 nm

Sheath Color

AB

OS2

NS

NS

NS

0.4 dB/km

0.3 dB/km

Yellow

CB

OM1

200 MHz-km

200 MHz-km

3.5 dB/km

1.0 dB/km

NS

Orange

GB

OM1

500 MHz-km

350 MHz-km

3.5 dB/km

1.0 dB/km

NS

Orange

ZB

OM2

500 MHz-km

500 MHz-km

3.5 dB/km

1.5 dB/km

NS

Orange

LB

OM2+

950 MHz-km

700 MHz-km

3.0 dB/km

1.0 dB/km

NS

Orange

EB

OM3

2000 MHz-km

1500 MHz-km

3.0 dB/km

1.0 dB/km

NS

Aqua

FB

OM4

4700 MHz-km

3500 MHz-km

3.0 dB/km

1.0 dB/km

NS

Aqua

XB

OM4+

4900 MHz-km

3675 MHz-km

3.0 dB/km

1.0 dB/km

NS

Aqua

NS = Not Specified


 TOP
Manufacturing Release

IMPORTANT NOTICE: This product specification is provided for informational purposes only in order to illustrate typical product constructions, applications and/or methods of installation. Because conditions of actual installation and use are unique and will vary, Berk-Tek makes no representation or warranty as to the reliability, accuracy or completeness of this data, even if Berk-Tek is aware of the product's intended use or purpose. Furthermore, this data does not constitute, nor should it be regarded or relied upon, as professional engineering advice. Installation of cable should only be done by qualified personnel and in conformance with all safety, electrical and other applicable codes, standards, rules or regulations. Appropriate and correct product selection, installation and use, and compliance with all such codes, standards, rules and regulations, is a customer/end-user responsibility. Product specifications, standards, programs or services are subject to improvement or changes without notice. Berk-Tek accepts no liability for typographical errors, technical inaccuracies, omissions or misuse of the information contained herein. Changes will be periodically made to address any such issues.


 TOP
   Fiber Specifications PS0309.revR (35 kB)
   Armor-Tek Brochure (705 kB)
   Armor Bonding Guide (61 kB)
   Armor-Tek Pulling Grip Instructions (383 kB)

Breakout Kits - Loose Tube   Breakout Kits - Loose Tube



Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map