6 x OM2 Premise Distribution Low Smoke Zero Halogen Indoor Cable
|
|
|
|
|
Berk-Tek’s tight buffered, fiber optic cable is designed for installation in riser and horizontal environments and interbuilding backbone structures.
|
|
|
|
|
Standards
|
|
International
|
EN 50173; IEC 60332-1-2; IEC 60332-1-3; IEC 60332-2-2; IEC 60332-3-24 Cat.C; IEC 60332-3-25 Cat.D; IEC 60754-1; IEC 60754-2; IEC 61034-2; ISO/IEC 11801; NES 713
|
|
National
|
ANSI/ICEA S-83-596; Telcordia GR-409
|
|
Description
|
|
Berk-Tek's tight buffered cable is available with standard multimode, single-mode and GIGAliteTM fibers.
Construction
900 µm buffered fibers surrounded by aramid yarns. Sheathed using a special, state-of-the-art low smoke zero halogen polymer material.
All dielectric.
Outdoor Considerations
Black jacketed and water-blocked versions of LSZH cables are available upon request for outdoor installations. Outdoor versions feature UV and fungus resistant jacketing.
Applications
Berk-Tek's tight buffered cable is intended for all high speed data applications including:
- 10BASE-FL
- 100BASE-SX/100BASE-FX
- ATM 155/ATM 622
- 1000BASE-SX/1000BASE-LX
- Fibre Channel 1.062/2.125
- 10GBASE-SR/SW
- 10GBASE-LX4
- 40/100 GbE
Features
- Low Smoke Zero Halogen polymer used for jacket and subunits
- Flexible, small diameter, 900 µm tight buffered construction
- High tensile strength and small diameter design
- Six to 144 count fiber construction LSZH designs ideal for horizontal and backbone installation
- Single-mode, multimode, and hybrid designs available
- Water blocked versions, suitable for Indoor/Outdoor installations, in-conduit, below the frost line, are available
Benefits
- Cost-saving design, easy to install and terminate
- Provides for greater pulling distances thus reducing installation time
- Assurance that cables will meet required specifications for communication networking applications
- Broad design selection allows for mix and match of fiber components to specific networking applications
|
|
TOP
|
Characteristics
|
|
Fiber optic type
|
OM2 50/125
|
|
|
Type of cable
|
Tight Buffered (TB)
|
|
|
Outer sheath
|
LSZH
|
|
|
Sheath colour
|
Orange
|
|
|
Number of optical fibres
|
6
|
|
|
Nominal outer diameter
|
0.256in
|
|
|
Nominal outer diameter
|
6.5mm
|
|
|
Approximate weight
|
28lb/kft
|
|
|
Approximate weight
|
42kg/km
|
|
|
Optical performance
|
ZB (50/125 FDDI, OM2)
|
|
|
Attenuation, max. 850 nm (cabled)
|
3.5dB/km
|
|
|
Attenuation, max. 1300 nm (cabled)
|
1.5dB/km
|
|
|
Maximum installation tension
|
150lb
|
|
|
Maximum installation tension
|
667.0N
|
|
|
Max. Load. Long Term (lbs)
|
45.0lb
|
|
|
Max. Load. Long Term
|
200.0N
|
|
|
Impacts per TIA/EIA FOTP-25
|
2 at 5.88 N-m
|
|
|
Crush resistance per TIA/EIA FOTP-41
|
110N/cm
|
|
|
Cable flexibility per TIA/EIA FOTP-104
|
25 cycles
|
|
|
Minimum Bending Radius - Install
|
3.8in
|
|
|
Minimum Bend Radius - Install
|
9.8cm
|
|
|
Minimum Bending Radius - LongTerm
|
2.6in
|
|
|
Minimum Bending Radius - LongTerm
|
6.5cm
|
|
|
RoHS conform
|
Yes
|
|
|
Operating temperature, range
|
-40 .. 75°C
|
|
|
Ambient installation temperature, range
|
-20 .. 75°C
|
|
|
Storage temperature, range
|
-40 .. 85°C
|
|
|
Field of application
|
Indoor
|
|
TOP
|
Fiber Type
|
ISO-TIA Standard
|
Effective Modal BW @ 850 nm
|
Overfilled Launch BW @ 850 nm
|
Attenuation @ 850 nm
|
Attenuation @ 1300 nm
|
Attenuation @ 1550 nm
|
Sheath Color
|
|
AB
|
OS2
|
NS
|
NS
|
NS
|
0.7 dB/km
|
0.7 dB/km
|
Yellow
|
|
CB
|
OM1
|
200 MHz-km
|
200 MHz-km
|
3.5 dB/km
|
1.0 dB/km
|
NS
|
Orange
|
|
GB
|
OM1+
|
500 MHz-km
|
350 MHz-km
|
3.5 dB/km
|
1.0 dB/km
|
NS
|
Orange
|
|
ZB
|
OM2
|
500 MHz-km
|
500 MHz-km
|
3.5 dB/km
|
1.5 dB/km
|
NS
|
Orange
|
|
LB
|
OM2+
|
950 MHz-km
|
700 MHz-km
|
3.0 dB/km
|
1.0 dB/km
|
NS
|
Orange
|
|
EB
|
OM3
|
2000 MHz-km
|
1500 MHz-km
|
3.0 dB/km
|
1.0 dB/km
|
NS
|
Aqua
|
|
FB
|
OM4
|
4700 MHz-km
|
3500 MHz-km
|
3.0 dB/km
|
1.0 dB/km
|
NS
|
Aqua
|
|
XB
|
OM4+
|
4900 MHz-km
|
3675 MHz-km
|
3.0 dB/km
|
1.0 dB/km
|
NS
|
Aqua
|
|
NS = Not Specified
|
TOP
|
Manufacturing Release
|
|
IMPORTANT NOTICE: This product specification is provided for informational purposes only in order to illustrate typical product constructions, applications and/or methods of installation. Because conditions of actual installation and use are unique and will vary, Berk-Tek makes no representation or warranty as to the reliability, accuracy or completeness of this data, even if Berk-Tek is aware of the product's intended use or purpose. Furthermore, this data does not constitute, nor should it be regarded or relied upon, as professional engineering advice. Installation of cable should only be done by qualified personnel and in conformance with all safety, electrical and other applicable codes, standards, rules or regulations. Appropriate and correct product selection, installation and use, and compliance with all such codes, standards, rules and regulations, is a customer/end-user responsibility. Product specifications, standards, programs or services are subject to improvement or changes without notice. Berk-Tek accepts no liability for typographical errors, technical inaccuracies, omissions or misuse of the information contained herein. Changes will be periodically made to address any such issues.
|