8 x OM1+ Heavy Duty Breakout LSZH Riser with Interlock Armor - 2.0 mm subunit
|
New
|
|
|
|
Berk-Tek’s Heavy Duty Breakout cables with Interlock Armor are designed for installation in horizontal, industrial and other harsh environments where additional strength and fiber protection is required.
Heavy Duty Breakout cables incorporate 900 um tight buffered single-fiber aramid-filled subunits. The standard subunit diameter is 2.0 mm. Additional subunit diameters, including 1.6 mm and 2.5 mm are available. Design options include dielectric, and interlock armored, each with riser and low smoke zero halogen riser jackets.
These cables are tested to the mechanical and environmental requirements of Telcordia GR-409 and ANSI/ICEA S-83-596.
Berk-Tek’s Heavy Duty Breakout cables with Interlock Armor are available in Multimode, Single-mode, and GIGAliteTM fibers.
|
|
|
|
|
Standards
|
|
International
|
EN 50173; ISO/IEC 11801
|
|
National
|
ANSI/TIA-568-C.3; Telcordia GR-409
|
|
Description
|
|
Construction
Each cable utilizes individual subunits containing a single 900 um tight buffered fiber, surrounded by aramid yarns. Cable design accommodates from 2 to 48 fibers.
- Each fiber in an individual compact, numbered, aramid-filled subunit
- Tape wrapped dry core
- Colored high-strength ripcord
- Low Smoke Zero Halogen polymers used for tight buffer, subunit, core and outer jackets
- Aluminum interlock armor provides extra protection
Applications
Berk-Tek’s Heavy Duty Breakout cables are suitable for all passive and active optical network designs requiring high speed voice, video, and data applications, including (but not limited to):
- 10BASE-FL
- 100BASE-SX/100BASE-FX
- ATM 155/ATM 622
- 1000BASE-SX/1000BASE-LX
- Fibre Channel 1.062/2.125
- 10GBASE-SR/SW
- 10GBASE-LX4
- 40/100 GbE
Features
- Multimode, Single-mode, and GIGAliteTM fibers
- Available with new bend-insensitive single-mode fibers
- High tensile strength, crush resistant
- Aluminum interlock armored, steel interlock available
- Low smoke zero halogen riser rated design.
- Indoor/Outdoor dry water-blocked designs available
Benefits
- Eliminates the need for conduit or plenum innerduct
- Significant cost savings in both materials and labor - up to 25%
- Accommodates last minute relocations or pathway changes
- Provides a higher concentration of cables in an area than conduit
- Armor provides crush protection and protection from rodent attacks
|
|
TOP
|
Characteristics
|
|
Fiber optic type
|
OM1 62.5/125 Extended Distance
|
|
|
Type of cable
|
Tight Buffered (TB)
|
|
|
Outer sheath
|
LSZH-FR
|
|
|
Sheath colour
|
Orange
|
|
|
Armour type
|
Aluminum Interlock
|
|
|
Number of optical fibres
|
8
|
|
|
Tube diameter
|
2mm
|
|
|
Nominal outer diameter
|
0.73in
|
|
|
Nominal outer diameter
|
18.5mm
|
|
|
Approximate weight
|
188lb/kft
|
|
|
Approximate weight
|
279kg/km
|
|
|
Optical performance
|
GB (62.5/125 GIGAlite, OM1+ Extended Distance)
|
|
|
Attenuation, max. 850 nm (cabled)
|
3.5dB/km
|
|
|
Attenuation, max. 1300 nm (cabled)
|
1.0dB/km
|
|
|
Maximum installation tension
|
300lb
|
|
|
Maximum installation tension
|
1320.0N
|
|
|
Max. Load. Long Term (lbs)
|
90.0lb
|
|
|
Max. Load. Long Term
|
396.0N
|
|
|
Impacts per TIA/EIA FOTP-25
|
2 at 8.83 N-m
|
|
|
Crush resistance per TIA/EIA FOTP-41
|
440N/cm
|
|
|
Cable flexibility per TIA/EIA FOTP-104
|
100 cycles
|
|
|
Minimum Bending Radius - Install
|
11in
|
|
|
Minimum Bend Radius - Install
|
27.8cm
|
|
|
Minimum Bending Radius - LongTerm
|
7.3in
|
|
|
Minimum Bending Radius - LongTerm
|
18.5cm
|
|
|
RoHS conform
|
Yes
|
|
|
Operating temperature, range
|
-20 .. 75°C
|
|
|
Ambient installation temperature, range
|
-20 .. 75°C
|
|
|
Storage temperature, range
|
-40 .. 85°C
|
|
|
Field of application
|
Indoor
|
|
TOP
|
Fiber Type
|
ISO-TIA Standard
|
Effective Modal BW @ 850 nm
|
Overfilled Launch BW @ 850 nm
|
Attenuation @ 850 nm
|
Attenuation @ 1300 nm
|
Attenuation @ 1550 nm
|
Sheath Color
|
|
AB
|
OS2
|
NS
|
NS
|
NS
|
0.7 dB/km
|
0.7 dB/km
|
Yellow
|
|
CB
|
OM1
|
200 MHz-km
|
200 MHz-km
|
3.5 dB/km
|
1.0 dB/km
|
NS
|
Orange
|
|
GB
|
OM1+
|
500 MHz-km
|
350 MHz-km
|
3.5 dB/km
|
1.0 dB/km
|
NS
|
Orange
|
|
ZB
|
OM2
|
500 MHz-km
|
500 MHz-km
|
3.5 dB/km
|
1.5 dB/km
|
NS
|
Orange
|
|
LB
|
OM2+
|
950 MHz-km
|
700 MHz-km
|
3.0 dB/km
|
1.0 dB/km
|
NS
|
Orange
|
|
EB
|
OM3
|
2000 MHz-km
|
1500 MHz-km
|
3.0 dB/km
|
1.0 dB/km
|
NS
|
Aqua
|
|
FB
|
OM4
|
4700 MHz-km
|
3500 MHz-km
|
3.0 dB/km
|
1.0 dB/km
|
NS
|
Aqua
|
|
XB
|
OM4+
|
4900 MHz-km
|
3675 MHz-km
|
3.0 dB/km
|
1.0 dB/km
|
NS
|
Aqua
|
|
NS = Not Specified
|
TOP
|
Manufacturing Release
|
|
IMPORTANT NOTICE: This product specification is provided for informational purposes only in order to illustrate typical product constructions, applications and/or methods of installation. Because conditions of actual installation and use are unique and will vary, Berk-Tek makes no representation or warranty as to the reliability, accuracy or completeness of this data, even if Berk-Tek is aware of the product's intended use or purpose. Furthermore, this data does not constitute, nor should it be regarded or relied upon, as professional engineering advice. Installation of cable should only be done by qualified personnel and in conformance with all safety, electrical and other applicable codes, standards, rules or regulations. Appropriate and correct product selection, installation and use, and compliance with all such codes, standards, rules and regulations, is a customer/end-user responsibility. Product specifications, standards, programs or services are subject to improvement or changes without notice. Berk-Tek accepts no liability for typographical errors, technical inaccuracies, omissions or misuse of the information contained herein. Changes will be periodically made to address any such issues.
|