Hybrid 12 x OM2+ & 12 x OS2 Premise Distribution Riser Indoor/Outdoor Cable
|
|
|
|
|
Berk-Tek's riser rated Indoor/Outdoor Tight-Buffer cables are designed specifically for LAN/WAN campus and building backbone cabling infrastructure. Suitable for Indoor/Outdoor installations, in-conduit, below the frost line.
|
|
|
|
|
Standards
|
|
International
|
EN 50173; ISO/IEC 11801
|
|
National
|
ANSI/ICEA S-104-696; ANSI/ICEA S-83-596; ANSI/TIA-568-C.3; Telcordia GR-20; Telcordia GR-409
|
|
Description
|
|
This fiber optic cable is designed for installation in riser and horizontal environments and interbuilding backbone structures.
This design incorporates tight buffered optical fibers within a dry water blocked cable core (2-24 fibers) or 12-fiber subunits (36-144 fibers). Suitable for operation across wide temperature variations typically addressed by outside plant cables. No Buffer Tube Fanout kits are required. Direct termination is enabled.
Construction
Each cable utilizes our DryGel water blocking system in the cable core. Cable design can accommodate from 2-144 tight buffered (900 µm) fibers. A glass reinforced (GRP) anti-buckling member is centrally located within cables having fiber counts from 24-144.
All dielectric.
Interlocking Armor (Armor-Tek) versions are available using aluminum or steel armor.
Outdoor Considerations
For use in conduit, below the frost line.
Loose Tube cables are recommended if interbuilding conduit systems lie above the frost line and are likely to fill with water.
- Tight Buffer fiber cables are not suitible for aerial-lashed installations.
Applications
Berk-Tek's tight buffered cable is intended for all high speed data applications including:
- 10BASE-FL
- 100BASE-SX/100BASE-FX
- ATM 155/ATM 622
- 1000BASE-SX/1000BASE-LX
- Fibre Channel 1.062/2.125
- 10GBASE-SR/SW
- 10GBASE-LX4
- 40/100 GbE
Features
- Flexible, small diameter, 900 µm tight buffered construction
- High tensile strength and small diameter design
- 2 to 144 count fiber construction riser indoor/outdoor designs ideal for horizontal and backbone installation
- Single-mode, multimode, and hybrid designs available
- Also available in low smoke zero halogen design
Benefits
- Cost-saving design, easy to install and terminate
- Provides for greater pulling distances thus reducing installation time
- Assurance that cables will meet required specifications for communication networking applications
- Broad design selection allows for mix and match of fiber components to specific networking applications
- One cable design meeting all structured cabling network communications applications
|
|
TOP
|
Characteristics
|
|
Fiber optic type
|
OM2 50/125 Extended Distance / Single-mode 9/125
|
|
|
Type of cable
|
Tight Buffered (TB)
|
|
|
Outer sheath
|
Riser
|
|
|
Sheath colour
|
Black
|
|
|
Number of optical fibres
|
24
|
|
|
Nominal outer diameter
|
0.335in
|
|
|
Nominal outer diameter
|
8.5mm
|
|
|
Approximate weight
|
47lb/kft
|
|
|
Approximate weight
|
70kg/km
|
|
|
Optical performance
|
Hybrid LB (50/125 GIGAlite, Exceeds OM2) / AB (Single-mode, OS2)
|
|
|
Attenuation, max. 850 nm (cabled)
|
3.0dB/km
|
|
|
Attenuation, max. 1300 nm (cabled)
|
1.0dB/km
|
|
|
Attenuation, max. 1310 nm (cabled)
|
0.7dB/km
|
|
|
Attenuation, max. 1550 nm (cabled)
|
0.7dB/km
|
|
|
Maximum installation tension
|
150lb
|
|
|
Maximum installation tension
|
667.0N
|
|
|
Max. Load. Long Term (lbs)
|
45.0lb
|
|
|
Max. Load. Long Term
|
200.0N
|
|
|
Impacts per TIA/EIA FOTP-25
|
2 at 5.88 N-m
|
|
|
Crush resistance per TIA/EIA FOTP-41
|
100N/cm
|
|
|
Cable flexibility per TIA/EIA FOTP-104
|
100 cycles
|
|
|
Minimum Bending Radius - Install
|
5in
|
|
|
Minimum Bend Radius - Install
|
12.8cm
|
|
|
Minimum Bending Radius - LongTerm
|
3.4in
|
|
|
Minimum Bending Radius - LongTerm
|
8.5cm
|
|
|
RoHS conform
|
Yes
|
|
|
Operating temperature, range
|
-40 .. 75°C
|
|
|
Ambient installation temperature, range
|
-20 .. 75°C
|
|
|
Storage temperature, range
|
-40 .. 85°C
|
|
|
Field of application
|
Indoor, Outdoor
|
|
TOP
|
Fiber Type
|
ISO-TIA Standard
|
Effective Modal BW @ 850 nm
|
Overfilled Launch BW @ 850 nm
|
Attenuation @ 850 nm
|
Attenuation @ 1300 nm
|
Attenuation @ 1550 nm
|
Sheath Color
|
|
AB
|
OS2
|
NS
|
NS
|
NS
|
0.7 dB/km
|
0.7 dB/km
|
Black
|
|
CB
|
OM1
|
200 MHz-km
|
200 MHz-km
|
3.5 dB/km
|
1.0 dB/km
|
NS
|
Black
|
|
GB
|
OM1+
|
500 MHz-km
|
350 MHz-km
|
3.5 dB/km
|
1.0 dB/km
|
NS
|
Black
|
|
ZB
|
OM2
|
500 MHz-km
|
500 MHz-km
|
3.5 dB/km
|
1.5 dB/km
|
NS
|
Black
|
|
LB
|
OM2+
|
950 MHz-km
|
700 MHz-km
|
3.0 dB/km
|
1.0 dB/km
|
NS
|
Black
|
|
EB
|
OM3
|
2000 MHz-km
|
1500 MHz-km
|
3.0 dB/km
|
1.0 dB/km
|
NS
|
Black
|
|
FB
|
OM4
|
4700 MHz-km
|
3500 MHz-km
|
3.0 dB/km
|
1.0 dB/km
|
NS
|
Black
|
|
XB
|
OM4+
|
4900 MHz-km
|
3675 MHz-km
|
3.0 dB/km
|
1.0 dB/km
|
NS
|
Black
|
|
NS = Not Specified
|
TOP
|
Hybrid Fiber Types
|
|
| Tight Buffer Color & Marking |
Fiber Type |
| Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Rose, Aqua |
OM2+ |
| Hash Marked: Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Rose, Aqua |
OS1 |
|
TOP
|
Cross-section Diagram - PDR024-I/O
|
|

|
TOP
|
Manufacturing Release
|
|
IMPORTANT NOTICE: This product specification is provided for informational purposes only in order to illustrate typical product constructions, applications and/or methods of installation. Because conditions of actual installation and use are unique and will vary, Berk-Tek makes no representation or warranty as to the reliability, accuracy or completeness of this data, even if Berk-Tek is aware of the product's intended use or purpose. Furthermore, this data does not constitute, nor should it be regarded or relied upon, as professional engineering advice. Installation of cable should only be done by qualified personnel and in conformance with all safety, electrical and other applicable codes, standards, rules or regulations. Appropriate and correct product selection, installation and use, and compliance with all such codes, standards, rules and regulations, is a customer/end-user responsibility. Product specifications, standards, programs or services are subject to improvement or changes without notice. Berk-Tek accepts no liability for typographical errors, technical inaccuracies, omissions or misuse of the information contained herein. Changes will be periodically made to address any such issues.
|
TOP
|