Description
Standards
National : UL 1479; UL 1569; UL 83Description
Applications
ENERGEX® MC 120 cables may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction. They are suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC 2008 and NEC 2011 Articles 230.43, 300.22(C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC 2008 and NEC 2011 Article 300.22(C) ONLY.
Nexans MC 120 wire is LEAD FREE and RoHS compliant.
Construction
Conductor:
Bare annealed copper conforming to to ASTM B3.
Insulation:
PVC/Nylon Type THHN in accordance with UL 83, flame retardant meeting UL VW-1 flame test.
Ground Wire:
Green PVC/Nylon Type THHN insulation sized in accordance with NEC 2008 and NEC 2011 and UL.
Assembly:
Conductors are cabled with grounding wires. A marker tape/core protection tape combination assembles the core in an essentially round configuration.
Armor:
Interlocking galvanized steel tape armor applied directly over the core.
Marker Tape Print
NEXANS TYPE MC 600 VOLT FOR CT USE (SIZE) THHN (UL) E-47409 LEAD FREE (MFG DATE)
Specifications
- Meets UL 83: Thermoplastic Insulated Wires and Cables
- Tested to UL 1479: Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to 2 AWG)
- Meets UL 1569: Metal Clad Cables
- Meets UL 1581: Reference Standard for Electrical Wires, Cables, and Flexible Cords
- Meets UL 2256: Wire and Cable Test Methods
- Designated Type MC per NEC 2008 and NEC 2011 Article 330
Docs and info
ENERGEX® MC 120 Steel Armored Cable
Part |
Number |
Conductor |
Ground |
Circuit Conductor |
Nominal Diameter |
Approximate |
Ampacity |
|||||
inches |
mm |
lb/kft |
kg/km |
60ºC |
75ºC |
90ºC |
||||||
250 ft |
1000 ft |
|
|
|
|
|
|
|
|
|
|
|
670033 |
670040 |
2 |
14 (1) |
14 (1) |
white/black |
0.44 |
11.2 |
144 |
214 |
15 |
15 |
15 |
670035 |
- |
3 |
14 (1) |
14 (1) |
white/black/red |
0.47 |
11.9 |
167 |
249 |
15 |
15 |
15 |
670036 |
670043 |
4 |
14 (1) |
14 (1) |
white/black/red/blue |
0.50 |
12.7 |
189 |
281 |
15¹ |
15¹ |
15¹ |
670011 |
670044 |
2 |
12 (1) |
12 (1) |
white/black |
0.48 |
12.1 |
179 |
266 |
20 |
20 |
20 |
670012 |
670045 |
3 |
12 (1) |
12 (1) |
white/black/red |
0.51 |
12.9 |
213 |
317 |
20 |
20 |
20 |
670013 |
670046 |
4 |
12 (1) |
12 (1) |
white/black/red/blue |
0.54 |
13.8 |
247 |
368 |
20¹ |
20¹ |
20¹ |
670014 |
670047 |
2 |
10 (1) |
10 (1) |
white/black |
0.54 |
13.8 |
238 |
354 |
30 |
30 |
30 |
670015 |
670048 |
3 |
10 (1) |
10 (1) |
white/black/red |
0.58 |
14.8 |
287 |
427 |
30 |
30 |
30 |
670016 |
670049 |
4 |
10 (1) |
10 (1) |
white/black/red/blue |
0.63 |
16.0 |
333 |
496 |
30¹ |
30¹ |
30¹ |
- |
- |
2 |
12 (19) |
12 (19) |
white/black |
0.48 |
12.3 |
215 |
320 |
20 |
20 |
20 |
- |
- |
3 |
12 (19) |
12 (19) |
white/black/red |
0.51 |
13.1 |
252 |
375 |
20 |
20 |
20 |
- |
- |
4 |
12 (19) |
12 (19) |
white/black/red/blue |
0.55 |
14.0 |
290 |
432 |
20¹ |
20¹ |
20¹ |
- |
- |
2 |
10 (19) |
10 (19) |
white/black |
0.55 |
14.0 |
164 |
244 |
30 |
30 |
30 |
- |
- |
3 |
10 (19) |
10 (19) |
white/black/red |
0.59 |
14.9 |
207 |
308 |
30 |
30 |
30 |
- |
- |
4 |
10 (19) |
10 (19) |
white/black/red/blue |
0.64 |
16.3 |
244 |
363 |
30¹ |
30¹ |
30¹ |
- |
- |
3 |
8 (19) |
10 (19) |
white/black/red |
0.71 |
18.1 |
300 |
446 |
40 |
50 |
55 |
- |
- |
3 |
6 (19) |
8 (19) |
white/black/red |
0.81 |
20.6 |
435 |
647 |
55 |
65 |
75 |
Bend Radius: 7 x overall diameter |
Selling information
Product Features
- Cables are UL listed as Type MC, 600 V
- UL listed insulated conductors
- Fire Wall Penetration rated depending on type of installation and fire-stop system used
- UL listed for use in cable trays per NEC 2008 Article 330.10(A)(6) or NEC 2011 Article 330.10(6)
- For use in Class I, Div. 2 per NEC 501.10(B)(1), Class II, Div.2 per NEC 2008 and NEC 2011 Article 502.10(B)(1) and Class III, Div. 1 & 2 per NEC 2008 and NEC 2011 Article 503.10 with approved termination fittings.
- Temperature rating of 90ºC dry
- Excellent mechanical & physical properties
- Standards Nexans ENERGEX® MC 120 is Lead Free and RoHS compliant
Options
The following constructions can be provided on special orders:
- Special conductor counts