Description
Standards
International : ISO/IEC 11801National : ANSI/TIA-568-C.2; UL 444
Description
Construction
26 AWG stranded tinned copper wire insulated with HDPE. Two insulated conductors twisted together to form a pair. Four such pairs and a cross filler form the basic unit, enclosed by polypropylene tape and shielded with an aluminum/polyester tape and 75% optical coverage braid contained within a TPE jacket.
Related Standards
Low Voltage - EU Directive 2014/35/EU, CE Approved
RoHS - EU Directive 2011/65/EU
PoE+ - Type 2 (802.3at)
Ratings | ||
---|---|---|
Description | Method | |
Listed Type | UL1666 | CMR |
Listed Type | UL444 | CMX Outdoor |
Oil Resistance | UL1277 11.2 | II (75°C) |
Sunlight Resistance | UL444 7.22 | Yes (720 hrs) |
Attributes | ||
Description | Method | |
AWM Style | UL758 | 2463 (600V, 80°C) |
Flex Life | Trailing Chain > 10x OD | 1 million cycles |
Flex Life | Trailing Chain > 16.97x OD | 10 million cycles |
Flex Life | Torsion (+/- 270°) | 3 million cycles |
Installation Pull Tension (Max): | ||
Bend Radius: > 3 inch | Internal | 40 lbs. |
Bend Radius: > 1.16 inch | TIA 568-C.0 | 25 lbs. |
Abrasion | UL2556 7.10 | 75 cycles/1.5 lb. load |
Characteristics
Construction characteristics | |
---|---|
Type of cable | SF/UTP |
Conductor material | 26 AWG Stranded Tinned Copper (7/34) |
Filler | HDPE Cross Filler |
Insulation | HDPE |
Jacket Material | TPE |
Braid | Tinned copper - 75% optical coverage |
Shielding | Aluminum/Polyester |
Core Tape | Foamed polypropylene |
Colour | Teal |
Dimensional characteristics | |
Insulated conductor diameter (Nominal) | 0.034in |
Average jacket thickness | 0.033in |
Minimum jacket thickness at any point | 0.026in |
Cable diameter (max.) | 0.332in |
Cable diameter (Nominal) | 0.29in |
Nominal cable weight | 40lb/kft |
Length per reel | 1000.0ft |
Electrical characteristics | |
Mutual capacitance | 5.6 nF/100m max. |
DC Resistance (max.) | 9.38Ohm/100m |
DC resistance unbalance (max.) | 4% |
Nominal velocity of propagation | 68% |
Maximum pair to ground unbalance | 330pF/100m |
Transmission characteristics | |
Skew (max.) | 45ns/100m |
Insertion loss de-rating factor | 1.5 |
Usage characteristics | |
Packaging | Reel |
Minimum Bending Radius - Install | 2.32in |
Recommended installation temperature range | -20 .. 80°C |
Recommended operating temperature range | -40 .. 80°C |
Recommended storage temperature range | -40 .. 80°C |
Maximum cable length | 66m |
Cold Bend | -40°C |
Weld spatter resistance | Yes |
Docs and info
-
LANmark-C637 - Technical Information
Electrical Characteristics Parameter Frequency Equation RL (dB) 1-10 MHz 20+5*Log(F) 10-20 MHz 25 20-500 MHz 25-7*Log(F/20) Insertion Loss (dB/100m) 1-500 MHz 1.5(1.82*√F+.0091*.25/√F) NEXT (dB) 1-500 MHz 44.3-15*log(F/100) PS-NEXT (dB) 1-500 MHz 42.3-15*log(F/100) ACR (dB/100m) 1-500 MHz NEXT - Insertion Loss PS-ACR 1-500 MHz PS-NEXT - Insertion Loss ACRF (dB) 1-500 MHz 27.8-20*Log(F/100) PSACRF (dB) 1-500 MHz 24.8-20*Log(F/100) Propagation Delay 1-500 MHz 534+(36/√F) Max Transfer Impedance (mΩm) 1; 10; 30; 100 MHz 50; 100; 200; 1000 Min Coupling Attenuation (dB/100m) 30-100 MHz ≥ 85 100-1000 MHz ≥85-20*log(F/100) Transmission Characteristics Description ISO/IEC 11801 66 m Category 6A ANSI/TIA-568-C.2 66 m Category 6A Coupling Attenuation IEC 61156-5 Type I Transfer Impedance IEC 61156-5 Grade 2 Color Code Pair-1 White/Blue Blue Pair-2 White/Orange Orange Pair-3 White/Green Green Pair-4 White/Brown Brown