FIREX® TECK90 600 Volts

Description
Nexans FIREX® TECK90 Cables are intended for use in various primary and secondary industries, including chemical processing plants, refineries and general factory environments.
Description
Standards
National : CSA C22.2 N° 131; CSA C22.2 N° 239Description
Even in the most demanding industrial and resource industry applications, Nexans FIREX® TECK90 cables have proven to have a superior service and maintenance record.
FIREX® TECK90 Cables utilize low acid gas, low flame spread PVC jacket compounds to ensure maximum safety to personnel and equipment in the event of fire.
Applications
FIREX® TECK90 Cables, originally developed for use in Canadian mines, are flexible, resistant to mechanical abuse, corrosion resistant, compact and reliable. They are suitable for a wide range of applications, including ALL hazardous locations - Class I, Division 1 and 2; Class II, Division 1 and 2; and Class III.
Industries such as pulp and paper, chemical, petroleum and other primary and secondary manufacturing industries have used FIREX® TECK90 Cables, particularly in areas where cables are subject to the risk of mechanical damage and chemical attack.
Commercial applications for FIREX® TECK90 Cables include apartment buildings and commercial complexes.
FIREX® TECK90 Cables can be relocated easily because they are rugged and flexible. They can be used in both dry and wet locations in open wiring, in ventilated, non-ventilated and ladder-type cable troughs, in ventilated flexible cableways, and for direct burial.
TECK90 Cables are also suitable for service entrance installations - above and below ground.
Highlights
Nexans FIREX® TECK90 Cables are:
- Available from stock
- Versatile
- Flexible
- Resistant to Mechanical Abuse and Corrosion
- Compact and Reliable
- "HL" and "FT4" Rated per CSA
- 90°C to -40°C
- Low Acid Gas (AG14)
- Inner and outer jackets are sunlight resistant
- LEAD FREE
- RoHS compliant
Marking and Identification
The inner jackets of Nexans FIREX® TECK90 cables are printed: SUN RES.
The outer jackets of Nexans FIREX® TECK90 cables are printed: (mon/year) NEXANS FIREX®-II TECK90 XLPE (-40°C) CSA LL19376 F HL FT4 AG14 SUN RES along with conductor size, number of conductors and sequential metre marking.
Conductor Identification:
2 Conductors: Black, White
3 Conductors: Red, Black, Blue
4 Conductors: Red, Black, Blue, White
5 or More Conductors: Black with Number Coding
Characteristics
Construction characteristics | |
---|---|
Conductor material | Copper |
Electrical characteristics | |
Maximum operating voltage | 600V |
Usage characteristics | |
Maximum operating temperature | 90°C |
Specific characteristics | |
See all products | |
|
Products and services
Docs and info
10 AWG TECK90 600 V 12 AWG Bonding Conductor Ampacity 30 A*
Number of |
Insulation |
Inner Jacket |
Nominal Diameters |
Approximate Net |
Approximate |
||||||||
Inner |
Armour |
Outer |
|||||||||||
inches |
mm |
inches |
mm |
inches |
mm |
inches |
mm |
inches |
mm |
lb/kft |
kg/km |
kg/km |
|
2 |
0.030 |
0.76 |
0.045 |
1.14 |
0.452 |
11.48 |
0.684 |
17.37 |
0.769 |
19.53 |
272 |
405 |
128 |
3 |
0.030 |
0.76 |
0.045 |
1.14 |
0.481 |
12.23 |
0.712 |
18.08 |
0.798 |
20.27 |
339 |
504 |
176 |
4 |
0.030 |
0.76 |
0.045 |
1.14 |
0.56 |
14.22 |
0.783 |
19.89 |
0.867 |
22.02 |
383 |
570 |
225 |
|
|||||||||||||
5 |
0.030 |
0.76 |
0.06 |
1.52 |
0.604 |
15.35 |
0.833 |
21.16 |
0.918 |
23.32 |
421 |
627 |
274 |
6 |
0.030 |
0.76 |
0.06 |
1.52 |
0.671 |
17.04 |
0.9 |
22.86 |
0.985 |
25.01 |
517 |
770 |
323 |
7 |
0.030 |
0.76 |
0.06 |
1.52 |
0.699 |
17.75 |
0.928 |
23.57 |
1.018 |
25.85 |
539 |
802 |
371 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
8 |
0.030 |
0.76 |
0.06 |
1.52 |
0.726 |
18.44 |
0.954 |
24.23 |
1.047 |
26.59 |
617 |
918 |
420 |
9 |
0.030 |
0.76 |
0.06 |
1.52 |
0.766 |
19.45 |
1.006 |
25.55 |
1.094 |
27.79 |
633 |
942 |
469 |
10 |
0.030 |
0.76 |
0.06 |
1.52 |
0.84 |
21.33 |
1.1 |
27.94 |
1.188 |
30.18 |
776 |
1154 |
518 |
|
|||||||||||||
11 |
0.030 |
0.76 |
0.06 |
1.52 |
0.879 |
22.33 |
1.135 |
28.83 |
1.222 |
31.03 |
795 |
1183 |
566 |
12 |
0.030 |
0.76 |
0.08 |
2.03 |
0.917 |
23.29 |
1.178 |
29.92 |
1.266 |
32.16 |
885 |
1318 |
615 |
15 |
0.030 |
0.76 |
0.08 |
2.03 |
0.987 |
25.06 |
1.247 |
31.67 |
1.335 |
33.91 |
1056 |
1571 |
761 |
19 |
0.030 |
0.76 |
0.08 |
2.03 |
1.066 |
27.07 |
1.321 |
33.55 |
1.414 |
35.92 |
1209 |
1800 |
956 |
|
|||||||||||||
20 |
0.030 |
0.76 |
0.08 |
2.03 |
1.098 |
27.89 |
1.357 |
34.47 |
1.445 |
36.7 |
1291 |
1966 |
1005 |
25 |
0.030 |
0.76 |
0.08 |
2.03 |
1.229 |
31.22 |
1.504 |
38.2 |
1.596 |
40.54 |
1528 |
2274 |
1248 |
30 |
0.030 |
0.76 |
0.08 |
2.03 |
1.317 |
33.45 |
1.573 |
39.95 |
1.68 |
42.67 |
1770 |
2634 |
1492 |
37 |
0.030 |
0.76 |
0.08 |
2.03 |
1.494 |
37.96 |
1.769 |
44.93 |
1.864 |
47.35 |
2097 |
3027 |
1833 |
|
|||||||||||||
40 |
0.030 |
0.76 |
0.08 |
2.03 |
1.567 |
39.8 |
1.917 |
48.69 |
1.967 |
49.96 |
2298 |
3421 |
1979 |
50 |
0.030 |
0.76 |
0.08 |
2.03 |
1.701 |
43.21 |
2.051 |
52.1 |
2.105 |
53.47 |
2743 |
4082 |
2467 |
60 |
0.030 |
0.76 |
0.11 |
2.79 |
1.91 |
48.5 |
2.26 |
57.4 |
2.314 |
58.78 |
3303 |
4916 |
2954 |
80 |
0.030 |
0.76 |
0.11 |
2.79 |
2.133 |
54.18 |
2.483 |
63.07 |
2.57 |
65.28 |
4225 |
6288 |
3929 |
90 |
0.030 |
0.76 |
0.11 |
2.79 |
2.246 |
57.05 |
2.596 |
65.94 |
2.683 |
68.15 |
4656 |
6928 |
4416 |
*Canadian Electrical Code Table 5C will apply if cableis used for power applications or the conductors are |
12 AWG TECK90 600 V 14 AWG Bonding Conductor Ampacity 20 A*
Number |
Insulation |
Inner |
Nominal Diameters |
Approximate Net |
Approximate |
||||||||
Inner |
Armour |
Outer |
|||||||||||
inches |
mm |
inches |
mm |
inches |
mm |
inches |
mm |
inches |
mm |
lb/kft |
kg/km |
kg/km |
|
2 |
0.030 |
0.76 |
0.045 |
1.14 |
0.405 |
10.29 |
0.636 |
16.15 |
0.724 |
18.39 |
238 |
354 |
80 |
3 |
0.030 |
0.76 |
0.045 |
1.14 |
0.429 |
10.9 |
0.660 |
16.76 |
0.745 |
18.92 |
280 |
417 |
111 |
4 |
0.030 |
0.76 |
0.045 |
1.14 |
0.502 |
12.75 |
0.733 |
18.62 |
0.817 |
20.75 |
298 |
443 |
141 |
|
|||||||||||||
5 |
0.030 |
0.76 |
0.045 |
1.14 |
0.522 |
13.26 |
0.752 |
19.1 |
0.839 |
21.31 |
347 |
516 |
172 |
6 |
0.030 |
0.76 |
0.060 |
1.52 |
0.599 |
15.21 |
0.828 |
21.03 |
0.912 |
23.16 |
402 |
598 |
203 |
7 |
0.030 |
0.76 |
0.060 |
1.52 |
0.614 |
15.6 |
0.843 |
21.41 |
0.927 |
23.55 |
438 |
652 |
233 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
8 |
0.030 |
0.76 |
0.060 |
1.52 |
0.656 |
16.66 |
0.884 |
22.45 |
0.970 |
24.66 |
476 |
708 |
264 |
9 |
0.030 |
0.76 |
0.060 |
1.52 |
0.700 |
17.78 |
0.940 |
23.87 |
1.014 |
25.76 |
496 |
738 |
295 |
10 |
0.030 |
0.76 |
0.060 |
1.52 |
0.744 |
18.9 |
0.988 |
25.1 |
1.077 |
27.35 |
531 |
790 |
325 |
|
|||||||||||||
11 |
0.030 |
0.76 |
0.060 |
1.52 |
0.760 |
19.3 |
1.028 |
26.11 |
1.096 |
27.84 |
622 |
925 |
356 |
12 |
0.030 |
0.76 |
0.060 |
1.52 |
0.776 |
19.71 |
1.037 |
26.34 |
1.125 |
28.57 |
651 |
969 |
387 |
15 |
0.030 |
0.76 |
0.060 |
1.52 |
0.842 |
21.39 |
1.101 |
27.97 |
1.189 |
30.2 |
755 |
1123 |
478 |
19 |
0.030 |
0.76 |
0.080 |
2.03 |
0.905 |
22.99 |
1.160 |
29.46 |
1.233 |
31.32 |
937 |
1394 |
601 |
|
|||||||||||||
20 |
0.030 |
0.76 |
0.080 |
2.03 |
0.974 |
24.74 |
1.233 |
31.32 |
1.321 |
33.55 |
973 |
1448 |
632 |
25 |
0.030 |
0.76 |
0.080 |
2.03 |
1.093 |
27.76 |
1.348 |
34.24 |
1.436 |
36.47 |
1165 |
1733 |
785 |
30 |
0.030 |
0.76 |
0.080 |
2.03 |
1.167 |
29.64 |
1.421 |
36.09 |
1.509 |
38.32 |
1302 |
1938 |
938 |
37 |
0.030 |
0.76 |
0.080 |
2.03 |
1.308 |
33.22 |
1.583 |
40.2 |
1.678 |
42.62 |
1495 |
2224 |
1153 |
|
|||||||||||||
40 |
0.030 |
0.76 |
0.080 |
2.03 |
1.367 |
34.72 |
1.642 |
41.71 |
1.737 |
44.12 |
1593 |
2370 |
1245 |
50 |
0.030 |
0.76 |
0.080 |
2.03 |
1.483 |
37.67 |
1.758 |
44.65 |
1.853 |
47.06 |
1884 |
2804 |
1551 |
60 |
0.030 |
0.76 |
0.080 |
2.03 |
1.615 |
41.03 |
1.965 |
49.91 |
2.015 |
51.18 |
2311 |
3439 |
1857 |
80 |
0.030 |
0.76 |
0.110 |
2.79 |
1.865 |
47.37 |
2.215 |
56.26 |
2.269 |
57.63 |
3021 |
4495 |
2470 |
90 |
0.030 |
0.76 |
0.110 |
2.79 |
1.962 |
49.85 |
2.312 |
58.72 |
2.366 |
60.09 |
3318 |
4937 |
2777 |
14 AWG TECK90 600 V 14 AWG Bonding Conductor Ampacity 15 A*
Number |
Insulation |
Inner |
Nominal Diameters |
Approximate Net |
Approximate |
||||||||
Inner |
Armour |
Outer |
|||||||||||
inches |
mm |
inches |
mm |
inches |
mm |
inches |
mm |
inches |
mm |
lb/kft |
kg/km |
kg/km |
|
2 |
0.030 |
0.76 |
0.045 |
1.14 |
0.369 |
9.37 |
0.600 |
15.24 |
0.688 |
17.48 |
191 |
284 |
57 |
3 |
0.030 |
0.76 |
0.045 |
1.14 |
0.390 |
9.91 |
0.621 |
15.77 |
0.709 |
18.01 |
225 |
335 |
77 |
4 |
0.030 |
0.76 |
0.045 |
1.14 |
0.444 |
11.27 |
0.676 |
17.17 |
0.761 |
19.33 |
266 |
396 |
96 |
|
|||||||||||||
5 |
0.030 |
0.76 |
0.045 |
1.14 |
0.472 |
11.99 |
0.703 |
17.86 |
0.787 |
19.99 |
306 |
455 |
115 |
6 |
0.030 |
0.76 |
0.045 |
1.14 |
0.515 |
13.08 |
0.743 |
18.87 |
0.828 |
21.03 |
316 |
471 |
134 |
7 |
0.030 |
0.76 |
0.045 |
1.14 |
0.522 |
13.26 |
0.755 |
19.18 |
0.844 |
21.44 |
338 |
502 |
154 |
|
|
||||||||||||
8 |
0.030 |
0.76 |
0.060 |
1.52 |
0.597 |
15.16 |
0.825 |
20.96 |
0.909 |
23.09 |
384 |
571 |
173 |
9 |
0.030 |
0.76 |
0.060 |
1.52 |
0.608 |
15.45 |
0.836 |
21.23 |
0.923 |
23.44 |
409 |
609 |
192 |
10 |
0.030 |
0.76 |
0.060 |
1.52 |
0.671 |
17.04 |
0.898 |
22.81 |
0.984 |
24.99 |
448 |
667 |
212 |
|
|||||||||||||
11 |
0.030 |
0.76 |
0.060 |
1.52 |
0.679 |
17.25 |
0.906 |
23.01 |
0.992 |
25.18 |
466 |
693 |
231 |
12 |
0.030 |
0.76 |
0.060 |
1.52 |
0.700 |
17.78 |
0.927 |
23.55 |
1.013 |
25.73 |
489 |
728 |
250 |
15 |
0.030 |
0.76 |
0.060 |
1.52 |
0.750 |
19.05 |
0.990 |
25.15 |
1.090 |
27.69 |
583 |
868 |
308 |
19 |
0.030 |
0.76 |
0.060 |
1.52 |
0.835 |
21.21 |
1.073 |
27.25 |
1.157 |
29.39 |
748 |
1113 |
385 |
|
|||||||||||||
20 |
0.030 |
0.76 |
0.060 |
1.52 |
0.850 |
21.59 |
1.105 |
28.07 |
1.189 |
30.20 |
766 |
1140 |
404 |
25 |
0.030 |
0.76 |
0.080 |
2.03 |
0.983 |
24.99 |
1.239 |
31.47 |
1.326 |
33.68 |
852 |
1268 |
501 |
30 |
0.030 |
0.76 |
0.080 |
2.03 |
1.060 |
26.92 |
1.311 |
33.30 |
1.399 |
35.53 |
995 |
1481 |
597 |
35 |
0.030 |
0.76 |
0.080 |
2.03 |
1.152 |
29.26 |
1.372 |
34.85 |
1.488 |
37.80 |
1066 |
1587 |
693 |
|
|||||||||||||
40 |
0.030 |
0.76 |
0.080 |
2.03 |
1.179 |
29.95 |
1.431 |
36.35 |
1.519 |
38.86 |
1224 |
1822 |
790 |
50 |
0.030 |
0.76 |
0.080 |
2.03 |
1.282 |
32.56 |
1.535 |
38.99 |
1.642 |
41.71 |
1468 |
2184 |
982 |
60 |
0.030 |
0.76 |
0.080 |
2.03 |
1.435 |
36.45 |
1.710 |
43.43 |
1.850 |
46.99 |
1613 |
2400 |
1175 |
80 |
0.030 |
0.76 |
0.080 |
2.03 |
1.604 |
40.74 |
1.954 |
49.63 |
2.094 |
53.18 |
2132 |
3173 |
1561 |
90 |
0.030 |
0.76 |
0.080 |
2.03 |
1.689 |
42.90 |
2.039 |
51.79 |
2.183 |
55.44 |
2347 |
3494 |
1753 |
*Canadian Electrical Code Table 5C will apply if cable is used for |
Related documents
Selling information
- Non-metallic coverings of electrical cables can burn and may transmit fire when ignited.
- Burning non-metallic coverings may emit acid gases which are toxic and may generate dense smoke.
- Emission of acid gases may corrode metal in the vicinity; e.g. sensitive instruments and reinforcing rods in cement.