Indoor/Outdoor Riser CL3R (ACRC, HDRC)

Description
Berk-Tek’s Composite Copper/Fiber cables incorporate high bandwidth optical fibers with insulated copper TFFN or THWN conductors. A wide variety of design options are available including; up to eight #12 AWG solid conductors, up to 2 tight buffered fibers (HDRC) or 12 loose tube fibers (ACRC), and interlock armoring. These cables are listed as CMR and CL3R-OF/PLTC-OF. A key application of these cables is to extend the distance that powered devices can be installed from the power source in Power over Ethernet (PoE+) installations. 12 AWG conductors can increase this distance from 328 feet to several thousand feet. The powered device could be an IP camera, a wireless access point, or other building automation device located in an area where an electrical outlet is not readily available.

Description
Standards
International : EN 50173; ISO/IEC 11801National : ANSI/ICEA S-104-696; ANSI/TIA-568.3-D; Telcordia GR-409; UL 13; UL 444
Description
Construction
Each cable consists of multiple TFFN or THWN copper conductors and multiple fibers cabled together within an outer jacket. Cable design accommodates from 1 to 8 conductors and 1 to 12 fibers.
- Fibers can be tight buffered (HDRC) or in a loose tube (ACRC)
- Aluminum interlock armored cables available
Applications
Berk-Tek’s Composite cables are suitable for all power limited applications where optical fibers are needed. Specific applications include (but not limited to):
- Power over Ethernet (PoE+) length extension
- Combining control and communication in industrial pathways
- Common pathway for fiber backbone and Class 3 power supply
- ETHERNET: 10BASE – 400GBASE (10BASE, 100BASE, 1000BASE, 10GBASE, 40GBASE, 100GBASE, 400GBASE)
- Fibre Channel: 1G-FC – 128GFC (1, 2, 4, 8, 16, 32, 128 GFC)
- SONET: OC-1 – OC-768 (OC -1, 3, 12, 24, 48, 192, 768)
- SDH: STM-0 – STM-256 (STM-0, 1, 4, 16, 64, 256)
- OTN: OTU-1 – OTU4 (OTU1, 2, 2e, 2f, 3, 3e2, 4)
- CPRI: CPRI-1 – CPRI-9 (CPRI-1, 2, 3, 4, 5, 6, 7, 7a, 8, 9)
- PON (SMF ONLY): RFoG, APON, BPON, EPON, GPON, WDM-PON, NG-PON
Features
- Multimode, Single-Mode, and GIGAlite™ fibers
- CMR and CL3R-OF/PLTC-OF wet and dry rated
- Aluminum interlock armored designs available
Benefits
- Enables PoE+ equipment to be located more than 100 meters from the switch
- Cost savings versus installation of a new electrical outlet
- CMR and CL3R-OF/PLTC-OF ratings allow cable to be installed in communication pathways
- Ease of installation
- Broad design selection allows for mix and match of copper and fiber components to specific networking applications
- Armor option adds crush resistance and protection from rodent attacks
Products and services
Docs and info
Conductor Color Sequence
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
Black |
White |
Blue |
Yellow |
Brown |
Orange |
Purple |
Pink |
Sheath Colors
Fiber Type |
Core |
ISO-TIA |
Effective Modal |
Overfilled Launch |
Attenuation |
Attenuation |
Attenuation |
Sheath Color |
|
|
|
|
|
|
Loose Tube |
|
|
AB |
8.3 |
OS2 |
NS |
NS |
NS |
0.4 dB/km |
0.3 dB/km |
Black |
|
|
|
|
|
|
Tight Buffer |
|
|
AB |
8.3 |
OS2 |
NS |
NS |
NS |
0.5 dB/km |
0.5 dB/km |
Black |
CB |
62.5 |
OM1 |
200 MHz-km |
200 MHz-km |
3.5 dB/km |
1.0 dB/km |
NS |
Black |
EB |
50 |
OM3 |
2000 MHz-km |
1500 MHz-km |
3.0 dB/km |
1.0 dB/km |
NS |
Black |
FB |
50 |
OM4 |
4700 MHz-km |
3500 MHz-km |
3.0 dB/km |
1.0 dB/km |
NS |
Black |
XB |
50 |
OM4+ |
4900 MHz-km |
3675 MHz-km |
3.0 dB/km |
1.0 dB/km |
NS |
Black |
NS = Not Specified |
-
Manufacturing Release
IMPORTANT NOTICE: This product specification is provided for informational purposes only in order to illustrate typical product constructions, applications and/or methods of installation. Because conditions of actual installation and use are unique and will vary, Berk-Tek makes no representation or warranty as to the reliability, accuracy or completeness of this data, even if Berk-Tek is aware of the product's intended use or purpose. Furthermore, this data does not constitute, nor should it be regarded or relied upon, as professional engineering advice. Installation of product should only be done by qualified personnel and in conformance with all safety, electrical and other applicable codes, standards, rules or regulations. Appropriate and correct product selection, installation and use, and compliance with all such codes, standards, rules and regulations, is a customer/end-user responsibility. Product specifications, standards, programs or services are subject to improvement or changes without notice. Berk-Tek accepts no liability for typographical errors, technical inaccuracies, omissions or misuse of the information contained herein. Changes will be periodically made to address any such issues.