Description
Use in Aero engine services
Standards
National : ESW 1254-010-002Description
CORE
Stranded conductor
Nickel clad copper alloy
002 : 19 x 0.12 mm
INSULATION
Fire resistant insulation
Polyimide tape
PTFE tape
Characteristics
Electrical characteristics | |
---|---|
Operating voltage | 600V |
Usage characteristics | |
Recommended operating temperature range | -65 .. 260°C |
Fire resistant | Yes |
Oil resistance | Very good resistance to aircraft fluids |
Docs and info
Dimensions and Weights
|
||||||
Reference |
Size |
Gauge |
Finished cable |
|||
DC Resistance |
Diameter |
Weight |
||||
Min |
Max |
|||||
ESW1254-010-002 |
002 |
24 |
131 |
1.20 |
1.65 |
9.50 |
Selling information
Core identification :
White with a helical red stripe
Marking text :
ESW1254-010-002-FX-FF-**
FX = Country of origin
FF = Manufaturer‘s code
** = Year of production (ie. 14 = 2014)