Description
Miniature Triaxial Cable
Description
CORE
7 x 0.175 mm Strand
Silver plated copper alloy
Nom. diameter = 0.53 mm
INSULATION
PTFE
Diameter = 1.52 ± 0.08 mm
SHIELD
Silver plated copper 10/100
Coverage ≥ 65%
Nom. diameter = 1.98 mm
INNER JACKET
FEP
Diameter = 2.49 ± 0.10 mm
SHIELD
Silver Plated Copper 10/100
Coverage ≥ 65%
Nom. diameter = 2.94 mm
JACKET
FEP
Diameter = 3.50 ± 0.15 mm
Max. weight = 31 g/m
Strippability : mechanical device or automatic stripper
Characteristics
Usage characteristics | |
---|---|
Recommended operating temperature range | -65 .. 200°C |
Minimum static operating bending radius | 18mm |
Minimum dynamic operating bending radius | 35.0mm |
Flame retardant | FAR/JAR part 25 sec 25.869 (a)(4) Appendix F part 1 (3) |
Oil resistance | Good |
RoHS compliant | Yes |
Docs and info
-
Electrical Characteristics
Dry test voltage between core and shield : 2000Vac Inner and outer jacket dry impulse test : 5000 V Maximum operating voltage : 900V rms Operating frequency : up to 1.5 GHz Maximum ohmic resistance of conductor : 124 Ω/km Insulation resistance : ≥ 5000 MΩ.km between dielectric and shield : ≥ 1500 MΩ.km between shields Characteristic impedance : 50 ± 2 Ω Maximum linear capacitance : 105 pF/m at 1 kHz Nominal velocity of propagation : 208 500 km/s (69.5%) -
Attenuation and Power Handling
Frequency Max. Rated Power Max. Attenuation at 20°C (MHz) (W) (dB/100m) 10 1400 9.5 100 430 35 200 300 49 500 190 77 1000 130 108 1500 110 133
Selling information
Inner and Outer jacket color : Transparent green
With a marker tape placed beneath the outer jacket
Marking text : "KE FR F **"