SP 69899 - ASNE 0811 WY
Description
Bus lines for multiplexed transmission. Use for bus system MIL STD 1553
77 Ohms, AWG 26 - Shielded Pair
Description
77 Ohms, AWG 26 - Shielded Pair
Standards
National : ASNE 0811 WYDescription
CORE
AWG 26, 19 x 0.10 mm
Silver plated copper alloy
(EN2083)
Insulation: extruded PTFE
ASSEMBLY
2 cores + 2 PTFE fillers
Nominal Diameter = 1.60 mm
SHIELD
Silver plated copper 10/100
JACKET
FEP
Characteristics
Usage characteristics | |
---|---|
Recommended operating temperature range | -65 .. 200°C |
Minimum static operating bending radius | 15mm |
Flame retardant | FAR/JAR part 25 sec 25.869 (a)(4) Appendix F part 1 (3) |
Oil resistance | Good |
Docs and info
Dimensions and weight
|
||||||||||
Reference |
US |
CONDUCTOR |
INSULATION |
BRAID |
FINISHED CABLE |
|||||
Composition |
Ohmic resistance |
Diameter |
Ø Strand |
Ø Max. |
Overall diameter |
Weight |
||||
Mini. |
Max. |
Mini. |
Max. |
|||||||
SP 69899 |
26 |
19 x 0.10 |
146 |
0.75 |
0.85 |
0.10 |
2.00 |
2.40 |
2.60 |
19 |
-
Electrical and high frequency performances
Voltage rating : 250V Voltage withstanding : 1000V between conductors : 1000V between conductors and shield Jacket sperk test : 5000V Insulation resistance : ≥ 1500 MΩ.km Characteristic impedance : 77 ± 7Ω at 1 MHz Nominal mutual capacitance : 65 pF/m Nominal capacitance : 110 pF/m between 1 core and shield : 180 pF/m between cores and shield Nominal attenuation : 3.5 dB/100m at 1 MHz Maximum transfer impedance : 50 mΩ/m DC current : 50 mΩ/m at 1 MHz : 50 mΩ/m at 10 MHz : 100 mΩ/m at 30 MHz -
Identification
Colour of cores : White + Blue Colour of jacket : White Marking text : FILOTEX FRANCE ET 69899-** With (**) = Year of manufacturing (ie. 14 = 2014) Red marking for the main line : (Nexans reference = ETUDE 69899-01) Blue marking for the branch line : (Nexans reference = ETUDE 69899-02)