STUDY 69794 - EN 3375-004C WJ
Description
Data bus cable for multiplexed transmission.
77 Ohms, AWG 24 - Pair Double Shielded - High Temperature
Description
77 Ohms, AWG 24 - Pair Double Shielded - High Temperature
Standards
International : EN 3375-004Description
CORE
AWG 24, 19 x 0.12 mm
Silver plated high strength copper alloy
Fluoropolymer insulation
ASSEMBLY
2 cores twisted with 2 fillers
SHIELD
2 Silver plated copper braid
Strand diameter : 0.10 mm
JACKET
Fluoropolymer
Characteristics
Usage characteristics | |
---|---|
Recommended operating temperature range | -65 .. 200°C |
Minimum static operating bending radius | 26mm |
Flame retardant | FAR/JAR part 25 sec 25.869 (a)(4) Appendix F part 1 (3) |
Docs and info
Dimensions and weight
|
||||||||||||
Reference |
US |
CONDUCTOR |
INSULATION |
BRAID |
FINISHED CABLE |
|||||||
Composition |
Diameter |
Ohmic resistance |
Diameter |
Strand diameter |
Max. Diameter |
Overall diameter |
Weight |
|||||
Nom. |
Max. |
Nom. |
Max. |
Nom. |
Max. |
|||||||
Study 69794 |
24 |
19 x 0.12 |
0.59 |
0.62 |
109 |
1.05 |
1.30 |
0.10 |
3.50 |
3.65 |
3.90 |
37 |
-
Electrical and high frequency performances
Voltage rating : 600V AC Characteristic impedance : 77 ± 7 Ω Maximum capacitance : 78 pF/m Maximum attenuation : 3.6 dB/100m at 1 MHz Maximum transfer impedance : 15 mΩ/m DC : 5 mΩ/m at 1 MHz : 5 mΩ/m at 10 MHz : 10 mΩ/m at 30 MHz -
Identification
Colour of cores : Blue + White Colour of jacket : White
Jacket code 'none': . Colour of marking : Green.
Jacket code '01': . Colour of marking : Red for the main line.
Jacket code '02': . Colour of marking : Blue for the branch line.
Marking text : FILOTEX FRANCE ET 69794-**