Standards
International : NSA 935306 YKDescription
Construction
- 2 CORES
19 x 0.17 mm
Silver plated copper clad steel
Insulation :
Extrusion PTFE 1.40 ± 0.05 mm
Semi-conductor tape
∅ nom. = 1.58 mm
- GLASS FIBER FILLERS
- SEMI-CONDUCTOR TAPE
- SHIELD
Nickel plated copper
Kr>70%
∅ = 0.12 mm
- JACKET
Polyimide tape(s)
PTFE tape(s)
∅ Max. = 4.35 mm
Characteristics
Construction characteristics | |
---|---|
Core identification | Red, Blue |
Sheath colour | White |
Electrical characteristics | |
Operating voltage | 600V |
Minimum insulation resistance | 1000MOhm.km |
Nominal capacitance between cores | 100pF/m |
Nominal capacitance between cores and shield | 200pF/m |
Triboelectrical noise at 2 Hz | Displacement 40 mm pk-pk ≤10 pC |
Triboelectrical noise from 5 to 50 Hz | Displacement 5 mm pk-pk ≤1 pC |
Triboelectrical noise from 10 to 70 Hz | Displacement 2 mm pk-pk ≤0.15 pC |
Usage characteristics | |
Recommended operating temperature range | -55 .. 260°C |
Electro magnetic interference resistance | Yes |
Flame retardant | FAR/JAR part 25 sec 25.869 (a)(4) Appendix F part 1 (3) |
Oil resistance | Very good resistance to aircraft fluids |
Docs and info
Electrical Characteristics
|
||
Capacitance |
between cores |
100 pF/m |
between cores and screen |
200 pF/m |
|
Voltage withstanding |
between cores |
1500 Volts AC |
between cores and screen |
1500 Volts AC |
|
Voltage rating |
600 Volts AC |
|
Insulation resistance (core/core and core/screen) |
≥ 1000 MΩ.km |
|
Tribolelectrical noise |
at 2 Hz |
Displacement 40 mm pk-pk ≤ 10 pC |
from 5 to 50 Hz |
Displacement 5 mm pk-pk ≤ 1 pC |
|
from 10 Hz to 70 Hz |
Displacement 2 mm pk-pk ≤ 0.15 pC |
Selling information
Color of core : Red, Blue
Color of Jacket : White